Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CDXR77 | NO AUDIO | Found connector CN-101 disconnected due to excessive pullingon external audio output cables (CNJ401). | ||
Sony | CCDV101 | NO PLAYBACK RF | Traced problem to HR-10 board not receiving RP-5V on pin 7,however, had 5V on pin 19 (reg 5V) traced problem to L-236 open (236 wouldnot cause problem if the schematic were correct). | ||
Sony | CDXA30 | REVISION OF SERVICE BULLETIN NUMBER CAR0130 | The service bulletin tells you to connect pins 3 and 7 in theRMX2 to cure the distorted audio but in most cases the customer usuallysends in the CDX-A30 and not the RMX2. | ||
Sony | CDPC305 | INCORRECT PART NUMBER - SPINDLE MOTOR | Part number for spindle motor (M-101) is incorrectly listed inthe service manual. | ||
Sony | CDPC205 | INCORRECT PART NUMBER - SPINDLE MOTOR | Part number for spindle motor (M-101) is incorrectly listed inthe service manual. | ||
Sony | CDPC201 | INCORRECT PART NUMBER - SPINDLE MOTOR | Part number for spindle motor (M-101) is incorrectly listed inthe service manual. | ||
Sony | CDPC35 | INCORRECT PART NUMBER - SPINDLE MOTOR | Part number for spindle motor (M-101) is incorrectly listed inthe service manual. | ||
Sony | CCDV5000 | VERTICAL LINES IN PICTURE | Vertical, winding lines in picture, unstable raster. | ||
Sony | CCDV101 | VERTICAL LINES IN PICTURE | Vertical, winding lines in picture, unstable raster. | ||
Sony | CCDV99 | VERTICAL LINES IN PICTURE | Vertical, winding lines in picture, unstable raster. | ||
Sony | D25 | DISC WOULD NOT ROTATE WHEN PLAY PRESSED | When the Play button is pressed, disc spins intermittentlywith lid closed. With lid open and interlock defeated unit works.Particular problem with three-inch discs. | ||
Sony | CCDF70 | SUPERIMPOSER DISTORTION | When superimposer was engaged, picture would go intodistortion. This is the second camera with this problem. | ||
Sony | STRAV1010 | DISTORTED AUDIO IN ONE CHANNEL | Unit had distorted audio in one channel only after about twohours of undisturbed playing (any source input). Problem was mostnoticeable in dolby and hall but was there in all modes. Found R-581 atthe input to the dolby board was not installed at the fa | ||
Sony | ITA650 | NO AUDIO | Unit goes on line by itself - after unit is set in the outposition. | ||
Sony | TCFX120 | AUDIO DISTORTED - CAPSTAN BECOMES DISLODGED | We have had several reports of the capstan becoming dislodgedon this model. This generally occurs when the customer inserts thecassette incorrectly and tries to close the door. The retaining washergives way and the capstan is pushed back. |