SonyCFDW888
PART INFO DISCREPANCY: DUPLICATE REF. & PART NOS. (REF. 385) The service manual shows the same ref. number and part numberfor two parts which are totally different. The ref. number in question isref. # 385. The information shown in the manual is correct for the smallspring located below ref. # 365. We need the
SonyCCDTR200
IRIS STICKING The iris was sticking (closed). You can tap on the side ofthe lens and the iris would open.
SonyCFD765
NO PART NUMBER FOR CASSETTE LID ASSEMBLY There is no part number for cassette lid assembly B in theservice manual. I ordered part number X-3363-006-1 and X-3363-008-1 andthe same part was shipped. -HQ COMMENTS: WRPC has verified that the p/n for the A cassette lidfor both CFD-755 and CFD-765
SonyCCDF30
DISTORTED PICTURE ON PLAYBACK/REPLACE C330, C353, SS-86 BRD The unit produced a distorted picture with pre-recorded tapesand would not record. The RF envelope appeared distorted and looked somewhat like a sinewave. The input to the ATF IC250 pin 40 was a perfectsinewave also. I traced the signal back to the he
SonyCFD460
PART NUMBER FOR BELTS The part numbers for the tape deck drive belts were switched.The long belt ordered is the short belt and vice-versa.
SonyTAAX311
NEED PART NUMBERS FOR CONNECTION CORDS BETWEEN COMPONENTS The part numbers for the connecting cords between the TA andthe ST, the TC and the CDP are not listed in the service manual.
SonyCCDFX410
IR REMOTE NOT WORKING/DEFECTIVE FP-511 I refurbished and the unit had no functions with the remote.I checked pin 2 of IC401 on the MA93 board with the scope. Serial datawould change when the function was used. The camera would not respond.
SonyCCDFX410
AFTER REPLACING LS CHASSIS, NO EJECT/ADJUST CAM PLATE LS When the LS chassis was replaced, the unit would not eject.The main slider was not pushing the eject lever far enough. With the LSchassis removed, it would go into eject.
SonyCCDF501
INTERMITTENT CAMERA OPERATION/REPLACE S514 After the unit ran for a while in record, the power to camerawould become intermittent. The unit would go into standby and the tapewould cue and review all by itself.
SonySPP320
BASE LINE LIGHT ALWAYS ON - REPLACE X-501, P/N 1-577-300-21 After powering up the base, the line light was already on andthe relay was locking up the phone line. By comparing units, I found thatQ607 base must be high when not trying to access the phone line. Thisturns on Q607 which pulls the base of Q608 low to
SonyCCDM8U
AFTER RECORDING, WOULD PLAYBACK, NO CAPSTAN LOCK AND LP After the symptom occured, I attempted an adjustment for ATFrecord current. Page 73, 3-3-3 pin 1 of RP29 board did not have a signal.I traced into the camera block and found an open connection on the FP5flex cable.
SonyTAAV421
SURROUND SPEAKERS CUT OFF WHEN REAR VOLUME IS ADJ - IC401 When adjusting the rear volume, the surround speakers wouldpop and cut off.
SonyXRU330
ONE CHANNEL OUT ON TAPE (REPLACE HP101, P/N 1-543-717-11) The unit came in with one channel out on tape and it wasintermittent. Also, when changing direction on tape, the audio would gofrom the left channel to the right channel.
SonyCDPX779ES
MISTAKES IN SCHEMATIC VOLTAGES On the D power board, the left side of R969 shows -9.5vdc, andthe right side of R969 which hooks to the diodes shows -3vdc if you godown to CN956, pin 1. Also, if you follow the Q952 emitter which shows5.9v to the left, it changes to +7v. Also, the outp
SonyITA4000
RESISTOR NOT SHOWN IN SERVICE MANUAL There is a resistor located between CN202, pin 1, and RY101.It has on it 2R2 and looks to be a heavy wattage. Also, the part is badlyburnt due to a lightning strike. -HQ COMMENTS: This appears to be a fusible resistor that Tokyo probablyadded for UL ap


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.