SintomaCausaSoluçãoPor:
SonyTCW320S
CASSETTE JAMMED MAKING A GRINDING NOISE Deck B wouldn't cycle into any function and would make agrinding noise. Head base would not come up into play position. Iftransport was laid on its back with the cassette holder up, unit would op-erate correctly. Replacement of cycling gear did not fi
SonyTCW320
CASSETTE JAMMED MAKING A GRINDING NOISE Deck B wouldn't cycle into any function and would make agrinding noise. Head base would not come up into play position. Iftransport was laid on its back with the cassette holder up, unit would op-erate correctly. Replacement of cycling gear did not fi
SonyWMAF23
PART # & REFERENCE # MISSING FROM MANUAL - PLAY LEVER ASS'Y Need the part number and the reference number for the playlever assembly. This is the plastic lever assembly to which the playbackhead and flexible cable are attached. -HQ COMMENTS: The part that you need is included with the head andflexible cable whe
SonySTRAV920
UNIT IN PROTECTION Pin 47 IC-502 (Protection In) should be +5 volts. Measuredline voltage is 1.5 volts. Lifting pin voltage on pin remains 1.5 volts.
SonySLV575UC
"DQ-2" BOARD Enclosed is the main board and a DQ-2 board. There is noinformation on this DQ-2 board.
SonyCDPC35
NO DRAWER OPERATION WITH NEW "BD" BOARD With new BD board drawer would not open.
SonyHVC2200
NO VIDEO OUTPUT Camera had no output. Found low voltages on several sourcesproduced by T-1 on C-6 board. 145V source was ok and -6 was ok but +/-110V sources were about one third of normal. We completely unloaded allthe sources with no significant change in voltages.
SonyKV27EXR15
DOES NOT RETAIN, OR ERASE SOME MEMORY SETTINGS, ROM IC-102 Channels 80 through 87 cannot be erased. Trapezoid lookingpicture and top screen sides reduced. When adjusting pincushion phase inservice mode, correction will be achieved but ROM won't retain new settingin memory when unit is unplugged.
SonyCDPC205
INTERMITTENT OPERATION Unpredictable problem sometimes it has run away spindle motor.Sometimes it will not do anything.
SonyCCDV110
NO VIDEO ON CAMERA MODE Recording a while, unit will record audio but no video oncamera mode. Noticed camera power is off, but still VTR is on. Performedbattery down adjustment and its the same.
SonyXE8
SPECTRUM ANALYZER DISPLAY IS FULLY LIT Unit is newer type which uses Supplement 1. It has a problemreferenced in service bulletin No. CAR0128. This unit has the changesin place refered to in the service bulletin, unit has the same symptoms. -HQ COMMENTS: The Supplement 1 revision is not id
SonyMPF17W55D
AVAILABILITY OF A 3.5 INCH FACEPLATE The MPF17W55D is a 3.5 inch floppy disk drive that is packagedin a 5.25 inch enclosure. This means that it will physically fit in aslot made for 5.25 inch disk drive. However, there is no kit availablethat enables this disk drive to fit into a 3.5 inch
SonyKV1941R
TRANSISTOR SUBSTITUTE, Q-605 Transistor 2SA835 substitutes to 2SA968B. Pin configurationis different. Part mounts on heat sink and subs part will not mount dir-ectly. Is this a good part number. -HQ COMMENTS: Yes, this is a good part number. However, it may benecessary to bend
SonyD66
DISC DOES NOT SPIN When Play button was pressed sled moved and hit limit switchbut spindle motor will not turn. Found coil L-508 was open. This problemis not the first time.
SonyD11
DISC DOES NOT SPIN When play button was pressed sled moved and hit limitswitch but spindle motor will not turn. Found coil L-504 was open. Thisproblem is not the first time.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.