Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDV110 | "DC" MARK IN DISPLAY | Service bulletin No. CAM0199 instructs tech to replace abovepart if the DC mark appears in display. 180899021 now crosses to180899041 which still containes the DC mark. -HQ COMMENTS: Tokyo advises that 1-808-990-21 will be stocked again inWRPC and avai | ||
Sony | CCDV110 | NO VIDEO ON CAMERA MODE | Recording a while, unit will record audio but no video oncamera mode. Noticed camera power is off, but still VTR is on. Performedbattery down adjustment and its the same. | ||
Sony | CCDV110 | PART NUMBERS FOR BOARD TO BOARD CONNECTORS | A servicer needs the part numbers for CCD-V110 board to boardconnectors.Can you please give us part numbers for the following board to boardconnectors? VI-21 board CN201 to CC-6 board W901 (CV-9) VI-21 board CN209 to EM-1 board CN905 (VE- | ||
Sony | CCDV110 | NO OUTPUT - UNIT DEAD | No output (unit dead) F-903 fuse blown. | ||
Sony | CCDV110 | NO VIDEO 5V FROM DC TO DC CONVERTER | No video 5V from DC to DC converter. This 5VDC line measuredabout 20 Ohm to ground. C-208 was shorted. | ||
Sony | CCDV110 | UNIT SHUTS DOWN TRANSPORT | Transport would stop after a few seconds, also no reelcounter. Found no reel LED drive to sensors. Found C-302 shorted. | ||
Sony | CCDV110 | HARD CASE MODEL NUMBER | Is the LCV-812 the correct hard case for the CCD-V110? -HQ COMMENTS: Yes, the LCH-V200 may also be used. | ||
Sony | CCDV110 | NO REEL COUNTER OPERATION | Reel counter looks like its trying to count (1st digit seemsto flicker) but stays at zero. | ||
Sony | CCDV110 | NO TAPE IN UNIT - UNIT ACTED LIKE TAPE WAS IN | With no tape actually in unit, the unit take-up reel rotatedforward as if not enough tape on take-up reel to allow threading. Didthis about 3 times and then entered emergency shutdown. | ||
Sony | CCDV110 | EXCESSIVE NOISE ON TAPE | |||
Sony | CCDV110 | VERTICAL SMEAR FROM BRIGHT OBJECT | Have had two units come in for severe vertical smear frombright object. When camera is rotated, smear remains vertical. Foundsmear caused by DT61. | ||
Sony | CCDV110 | IC PART NUMBERS | ICs on (AF-23) not called out in parts list - yet servicerneeds approval on board. | ||
Sony | CCDV110 | NO DRUM SERVO | Drum would start up and immediately shut down. Found C520shorted - (30 OHMs). Voltages were not far from spec around problem area. | ||
Sony | CCDV110 | ZOOM NOT WORKING | No power zoom, no auto focus. | ||
Sony | CCDV110 | VIEWFINDER ROLLS IN CAMERA MODE ONLY | Camera mode picture in EVF rolled. But picture, in EVF, inVTR mode did not roll. Camera mode monitor (RF) output video did notroll. |