Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDTR9 | UPPER DRUM DOES NOT FIT ON LOWER DRUM ASSEMBLY | Upper drum assembly supplied by NPC will not fit on drummount. The replacement upper drum and the original drum are being sentfor your inspection. -HQ COMMENTS: Judging by the samples sent in, there may have been amachining problem with the new upper d | ||
Sony | CCDTR31 | UNABLE TO ENTER VCR MODE/PAGE D ADD. 21 SHOULD BE 00 | After replacing VS-95 board I am unable to enter VCR mode orshut the unit off. Loading average data from the LANC jig allowed unit toreturn to normal operation. -HQ COMMENTS: There are addresses on page D that must be entered forcorrect operation of th | ||
Sony | SLV595HF | EJECT BUTTON IS INOPERATIVE: RESOLDER IC901 PIN40 MF140 BD | The unit will not eject/ not all keys on the switch blockwork. The problem may be intermittent. At IC901, I found pin 40unsoldered. I found poor soldering around IC. | ||
Sony | TCW32 | MISSING PART NUMBER FOR THE PINCH ROLLER - 3-355-808-02 | No part number is given for the pinch roller. It's marked inthe service manual as not supplied. | ||
Sony | DD10EX | SERVICE MANUAL ERROR, ASSY REF 24 IS NOT AVAILABLE | Upon ordering, all that is received is the cover. None of theparts within the dotted line are mounted. | ||
Sony | CCDVX3 | UNIT JAMMED/REPLACED CAM GEARS | The unit came in jammed. I found two gears (394569701 and394570001) defective. | ||
Sony | D4 | IRREGULAR SPEED - BAD SPINDLE MOTORS, P/N X-2641-521-1. | Many reports of bad motors. Irregular speed causes ticking inaudio. If you hold motor and spin, you will feel the irregularities. -HQ COMMENTS: Your samples have been sent to Tokyo for evaluation. Wehave already sent samples to Tokyo in January 1993. | ||
Sony | ITD250 | HANDSET MUTES WHEN EXTENSION PHONE IS PICKED UP | Handset mutes when extension phone is picked up. This iscaused by line loading. The 12V off-hook line voltage of this unit getsloaded down to less than 6 volts when an extension phone is picked up.This unit will stop working at a line voltage less than | ||
Sony | ITD200 | HANDSET MUTES WHEN EXTENSION PHONE IS PICKED UP | Handset mutes when extension phone is picked up. This iscaused by line loading. The 12V off-hook line voltage of this unit getsloaded down to less than 6 volts when an extension phone is picked up.This unit will stop working at a line voltage less than | ||
Sony | ITD150 | HANDSET MUTES WHEN EXTENSION PHONE IS PICKED UP | Handset mutes when extension phone is picked up. This iscaused by line loading. The 12V off-hook line voltage of this unit getsloaded down to less than 6 volts when an extension phone is picked up.This unit will stop working at a line voltage less than | ||
Sony | CFD30 | PLASTIC CD HOLDER BREAKS | Plastic CD holder breaks at screw lobe near spindle motor. Isuspect that the cause is there is too much weight for 1 screw lobe tohold. I suggest modifying the CD Holder, reference 103 by adding ribbedsupports on the spindle motor end of the holder. -HQ | ||
Sony | KV32TW75 | NO VIDEO/AUDIO, HV OK, REMOVED SOLDER BRIDGE ON C1266 | The unit would turn on, but would not have any video or audio, high voltage was present. | ||
Sony | ICFSW55 | M3 WILL NOT PROGRAM- ALSO CANNOT ERASE MEMORY PRESETS | The memory position M3 will not program properly, also itcannot erase memory positions. | ||
Sony | SLV585HF | MECHANICAL NOISE IN CUE/REV/FF/REW: PULLY 309 X37277821 | A mechanical noise during cue/review and ff/rewind sounds asthough the capstan motor is dragging. | ||
Sony | SLV595HF | NO DRUM OR CAPSTAN MOTOR ROTATION: Q211 MA106 | No drum, or capstan motor rotation. |