SintomaCausaSoluçãoPor:
SonyCCDVX3
TOP OF PICTURE DISTORTED UNIT VIBRATES/REPLACE DRUM Picture was distorted. Replaced drum. Problem became worse.Replaced supply reel and back tension band. Still a problem. Took notethat unit had a vibration in play.
SonyCCDVX3
ZOOM STUCK - OPEN UNIT, NPF/ SEE SB CSV-3 #335 I have several units 34, 17534, 08, 17826, 44, 59856, and now12, 47526. The flex cable gets dimples in it from CR 42 board C046 andarea. The flex cable is NBO and the customers tend to get irate. 12,47526 says rush on it.
SonyCCDVX3
UNABLE TO PERFORM BACK FLANGE ADJ. Technician attempted to perform the back flange adjustment.Tried several times but unit would lock up before completing adjustment.
SonyCCDV99
SPEED CHANGES FROM SP TO LP DURING SCAN (C837) Refer to FPR O3609. Although replacing C833 effects a cure,additionaly replacing C837 further reduces the noise and enhances the longterm performance of this unit.
SonyCCDV5000
POOR VIDEO IN FORWARD SEARCH (TEARING): REF 304 LEFT COASTER Unit had excessive hitches in forward play, forward search hadan unusable picture.
SonyCCDV101
INT OR NO AUDIO/C562 LEAKS ONTO FEED OPENS CLOCK TO AU60 Int or no audio, checked data lines into AU60 PCB. Found noSCK. Followed trace back and was open (int). Found leaky cap C562 overfeed through.
SonyCCDTR91
PREMATURE TAPE END DETECTION/RESOLDER CONNECTORS ON SL32 5 min tape end comes on too soon intermittent. Is there a similar fix like SB CAM-0333 for the FX310? Please call 612-920-3655 EXT 319. -HQ COMMENTS: Please resolder all connectors on the SL-32 board. Thisusually corrects this problem.
SonyCCDTR91
NO COLOR IN VF DURING RECORD/RESOLDER X601 This camera would show no color in the viewfinder pictureduring record. It would, though, during playback. This was caused by apoor solder connection at X601 on the VC board. Although the crystal wasoperating it was pulled slightly off frequency by the r
SonyCCDTR91
GLASS ON CCD IMAGER CRACKED Horizontal line across picture in EVF and playback. I foundthat glass on CCD imager cracked in a half and it created line acrosspicture. So far, I have seen two of this type problem.
SonyCCDTR91
BLACK & WHITE VIEWFINDER VIDEO/REPLACE X601 There was no color in the viewfinder E-E only. Playback wasok. Found that X601 was drifting.
SonyCCDTR91
IC501 CHANGE IC501 875284249, description CXP80624A-025R is used. Thispart is not listed in KC system and cannot be ordered.
SonyCCDTR91
NO AUTOFOCUS OR ZOOM/REPLACE IC655 No autofocus or zoom.
SonyCCDTR91
UNIT WILL NOT GO INTO RECORD WHILE IN STANDBY/CHECK CN451 Unit is powered up and there is camera video but it will notswitch to record. -Resolder CN451 on DD55 bd.
SonyCCDTR808E
BLACK BARS ON LEFT SIDE OF SCREEN/CHANGE C353 TO 6.8UF Faint black noise bars appear on the left side of screen.They are approximately 1/2/to 3/4 inch wide. This occurs only on its ownrecording. Nothing can be seen E E. Prerecorded tapes no problem. Thisis noticed more in bright scenes.
SonyCCDTR71
MISSING PART # FOR CAPSTAN CONNECTOR Part # for capstan connector missing from SM. cn502 isnot part of FP-182 (W403) 1-630-591-11.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.