Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CDXC710 | LOADS DISC, WON'T CLAMP (CLEANED AREA BETWEEN REF 161 & 159) | Would load disc, but not clamp it. Found that the D-lever(ref. 161) was sticking, which prevented the TR circular rack gear toengage (this rack gear is not referred to in the service manual, but isatached to TR tension spring ref. 163). | ||
Sony | CDXC610 | LOADS DISC, WON'T CLAMP (CLEANED AREA BETWEEN REF 161 & 159) | Would load disc, but not clamp it. Found that the D-lever(ref. 161) was sticking, which prevented the TR circular rack gear toengage (this rack gear is not referred to in the service manual, but isatached to TR tension spring ref. 163). | ||
Sony | CDXC510 | LOADS DISC, WON'T CLAMP (CLEANED AREA BETWEEN REF 161 & 159) | Would load disc, but not clamp it. Found that the D-lever(ref. 161) was sticking, which prevented the TR circular rack gear toengage (this rack gear is not referred to in the service manual, but isatached to TR tension spring ref. 163). | ||
Sony | CDXC410 | LOADS DISC, WON'T CLAMP (CLEANED AREA BETWEEN REF 161 & 159) | Would load disc, but not clamp it. Found that the D-lever(ref. 161) was sticking, which prevented the TR circular rack gear toengage (this rack gear is not referred to in the service manual, but isatached to TR tension spring ref. 163). | ||
Sony | MDXC150 | BINDING OPT BLOCK ASSY | New optical block did not slide smoothly after installing inMD chassis. Found guide on opt. assy. was binding on the shaft (the guidefarthest away from lens, and which has two prongs that fit to SL2 shaft,(ref 158). | ||
Sony | CDXC490 | ERRATIC OPERATION FROM KEY SWITCHES, FOUND OPEN GROUND TRACE | All key switches function wrong. Examples: Select buttonwould turn unit off AM would switch FM function presets at wronglocations. | ||
Sony | CDXC590 | OPTICAL PICKUP/SERVO BOARD INCOMPATIBILITY (KSS-410A/313A) | The unit came in for service with type KSS-313A opticalpickup, which was defective. The type shown in the service manual isKSS-410A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit. | ||
Sony | CDXC490 | OPTICAL PICKUP/SERVO BOARD INCOMPATIBILITY (KSS-410A/313A) | The unit came in for service with type KSS-313A opticalpickup, which was defective. The type shown in the service manual isKSS-410A, which was ordered from NPC and installed in the unit, but thispickup did not work in the customer's unit. | ||
Sony | MDXC150 | SPINDLE MOTOR DOES NOT RUN (RESOLDERED IC201) | CLV would not spin. No voltage or signal from IC302 pin 2 &44. IC302 was getting its error signal (pin 41) from IC301 pin 39.This was a tough problem because this is the signal for both directionand initial kick spin of the CLV. | ||
Sony | MDXC150 | CAN'T SELECT CD CHANGER (FOUND OPEN TRACE NEAR CN500 PIN 7) | Could not select a CD changer. | ||
Sony | EXCD90 | UNEXPLAINED ERROR CODE IN TEST MODE: "E-A0" | An unexplained error code appeared on the display while in thetest mode. The code is E-A0. -HQ COMMENTS: Tokyo told us that program bugs may account forunexplained error codes. In this particular case, the E-A0 appears whenthe unit tried to eject the | ||
Sony | EXCD90 | ERROR CODE E44 | Servicer has unit that customer complained it dropped out oncein awhile. Servicer has not been able to duplice problem. Put unit intest mode. After 6 hours of playing E44 came up on display but unit kepton playing. Noted FPR 03252. Here's another er | ||
Sony | EXCD60 | UNEXPLAINED ERROR CODE IN TEST MODE: "E-A0" | An unexplained error code appeared on the display while in thetest mode. The code is E-A0. -HQ COMMENTS: Tokyo told us that program bugs may account forunexplained error codes. In this particular case, the E-A0 appears whenthe unit tried to eject the | ||
Sony | EXCD60 | ERROR CODE E44 | Servicer has unit that customer complained it dropped out oncein awhile. Servicer has not been able to duplice problem. Put unit intest mode. After 6 hours of playing E44 came up on display but unit kepton playing. Noted FPR 03252. Here's another er | ||
Sony | EXCD1RF | SKIPS WHEN PLAYING OUTER TRACKS (SEE BULLETIN 358R2 FOR FIX) | The unit skips when playing the outer (higher number) trackson the disc. |