Dicas Reparação




Modelo - Chassis MDXC150


Pesquisa: MDXC150 Enviar Dica Resolvida
Resultados 7
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyMDXC150
BINDING OPT BLOCK ASSY New optical block did not slide smoothly after installing inMD chassis. Found guide on opt. assy. was binding on the shaft (the guidefarthest away from lens, and which has two prongs that fit to SL2 shaft,(ref 158).
SonyMDXC150
SPINDLE MOTOR DOES NOT RUN (RESOLDERED IC201) CLV would not spin. No voltage or signal from IC302 pin 2 &44. IC302 was getting its error signal (pin 41) from IC301 pin 39.This was a tough problem because this is the signal for both directionand initial kick spin of the CLV.
SonyMDXC150
CAN'T SELECT CD CHANGER (FOUND OPEN TRACE NEAR CN500 PIN 7) Could not select a CD changer.
SonyMDXC150
NO AUDIO (FOUND AUDIO AMP IC700 DEFECTIVE) No audio. Found audio amp IC700 defective. -HQ COMMENTS: Tokyo has analyzed samples we sent them and havedetermined that the defects are ususally caused by excessive reversevoltage being applied to the IC, probably by the power antenna relayturning off
SonyMDXC150
IMPROVING DISPLAY READABILITY (CHANGE R966: 6.8K TO 4.7K) Customer may complain that it is difficult read the display.
SonyMDXC150
REMOVING KEYSWITCHES (USE PYRO-PEN JR. ON SETTING # 1) The keyswitches may be difficult to remove without damagingthe PCB.
SonyMDXC150
KEYSWITCHES FAIL The keyswitches fail. It is most often the SELECT key butcould be any key. Sometimes there are more than 1 bad switch on the samefaceplate. -HQ COMMENTS: The QA group in Tokyo has been notified and samples havebeen sent to them. An improved switch ha


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads