Sony | CDXA55 | DISC DOES NOT SPIN, NO OPTICAL PICKUP MOTION (REPLACE Q901) | Disc would load but not spin, and there was no opticoperation. The unit was missing +5 VDC from regulator IC901. | ||
Sony | CDXA55 | DISC UNLOADING INCOMPLETE, MAGAZINE WON'T EJECT | The CD returned to the correct slot, but not completely intothe slot. This was caused by slider #115 not moving. Found stud of theDR gear (ref. #112) broken. | ||
Sony | CDXA55RF | EXCESSIVE SKIPPING (BROKEN SPRING, REFERENCE #7) | Complaint is excessive skipping. The chassis was rattlingloose inside case. Found spring broken on optic side of chassis and bothdampers ruptured. | ||
Sony | CDXA55 | PART NUMBER CORRECTION: CONNECTOR FLEXIBLE BOARD (REF. 102) | This flex cable does not fit in unit. This part # shows upin the system for model CDX-U300. The part number taken from the flexconnector of the CDX-A55 is 1-643-777-11, which substitutes to1-646-391-11. | ||
Sony | CDXA55 | INCORRECT PART NUMBERS (GEARS, REF. 108 AND REF. 222) | When ordered, this gear comes together with the lever assembly(X-3362-328-1). The gear, however, is smaller than the original andcannot work in the unit. On page 27, Reference No. 108, Part No.3-364-422-01 is the correct part. These two parts should b | ||
Sony | CDXA55RF | WILL NOT LOAD DISCS | Unit would not load discs, and D-451 was not turning on. |