Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CDPC705 | INTERMITTANT SHUFFLE - RE-GREASED DISC TRAY WASHER | Shuffle function will forget disc (the disc willintermmitantly not align properly with BU bracket and display will read nodisc) | ||
Sony | CDPC705 | DISK TRAY BASE WARPED | NRC had sent a CDP-C705 to the Technical Dept. The unit had aproblem with the chucking assy. aligning with the spindle motor assembly.We found the problem to be a warped disk table assy., Ref. No. 69 in theS/M.To Tokyo: I am sending one (1) sample of th | ||
Sony | CDPC705 | SKIPS | Unit skips, even after optic has been changed, this modelseems to be very susceptible to shock, much more so then lesser qualityunits. -HQ COMMENTS: Under normal circumstances the unit should not skip.However, if placed in an area where that is prone to | ||
Sony | CDPC70 | SKIPS - CLEANING OPTICS RESTORED OPERATION | Unit came in for skipping or intermittent no play. Confirmedbad optic 884812711. Unit was returned 2 weeks later same problem, skipsintermittently takes long time to play. Confirmed adjs. were OK. | ||
Sony | CDPC70 | WIRE HARNESS 2 FOR CDPC MODELS, HI-FI S/B NO.127 | Part number 1-946-073-11 ordered as per Hi-Fi service bulletinno.127. The side with the four male pins on it looks like it shouldreplace the socket on the board. If it is installed that way, the cableis too short to reach. I went through all the FPRs | ||
Sony | CDPC70 | NEED PART NUMBER FOR FRAME | No part number is listed in the service manual for frame. -HQ COMMENTS: A service bulletin was issued on July 25, 1989. It isHi-Fi #078. P/N for the frame is 4-924-407-06. A plastic pin whichretains the one of the table drive gears is missing on the | ||
Sony | CDPC705 | TORN PRINT ON PCB | When you remove IC-102 with Pyro pen, too much glue has beenput underneath IC. When you try to remove the IC, the print tears up thecircuit board. -HQ COMMENTS: The glue used is necessary during the manufacturingprocess to secure the components to the | ||
Sony | CDPC705 | TURNTABLE CONTINUALLY ROTATES | The turntable continually rotated. All front panel controlswere inoperative. We found the problem to be a poor connection at IC-302/pin 42. Resoldering resolved the problem. | ||
Sony | CDPC70 | TEST MODE INFORMATION | Cannot put the unit in test mode to check various functions.The service manual has no test mode info. -HQ COMMENTS: Tokyo fax (A910119): To put the unit in test mode:A. To play DISC 5: 1. Ground IC-301/pin 47 (CHECK TP) 2. Turn unit ON | ||
Sony | CDPC700 | DISC TRAY CONTINUOUSLY ROTATES BACK AND FORTH | Disc tray would rotate back and forth when unit was turned on.You could open and close tray but tray would continue to rotate back andforth. | ||
Sony | CDPC705 | DISC TABLE WILL NOT ROTATE | On some units the bracket which houses the optical devicecontacts the base of the player. This causes the table not to rotate orthe disc won't play. -HQ COMMENTS: The cause of the problem is the metal base warpingupward, when the bracket drops it does | ||
Sony | CDPC700 | CLOUDY LENS IN NEW KSS-150A | Pulled a new optical block out of stock and noticed it had acloudy lens. I did not use it. | ||
Sony | CDPC70 | DRAWER DOES NOT OPEN | Drawer would not open. Tray would rotate within the unitevery time Open button was pushed. SW-103 (drawer-in switch) was jammedin and would not open up due to a crack in the moveable part of theswitch. This fooled system control into thinking drawer w | ||
Sony | CDPC70 | DRAWER INTERMITTENTLY CLOSES AT COMPLETION OF OPEN ACTION. | Intermittently the drawer will close as soon as it reachesits open-most position. Holding the drawer from opening all the waydoes not cause it to close. (This is normal). | ||
Sony | CDPC70 | IT WILL NOT PLAY THE FIRST TRACK OF EAGLES CD | It will not play No. 1 track of the Eagles Hotel CaliforniaAsylum 103-2 (253051) Warner Bros. -HQ COMMENTS: Thank you for this information. We are still compilingthe list of bad discs. If you find anymore, let us know. |