Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CCDTR70 | NO EJECT (FOUND BAD CONNECTIONS ON VS112 MCB) | No eject. | ||
Sony | CCDTR70 | NO EVF ON BATTERY OPERATION | When DC input dropped below 6.2V, EVF blanked out. The camerastill operated normally. Found the Battery Down adjust was fine. | ||
Sony | CCDTR70 | DRUM SPINS FAST (FOUND X502 BAD) | Drum spins fast. | ||
Sony | CCDTR700 | AWB ADJUSTMENT PROBLEM; NO DDS DISPLAY; INPUT DATA D:21:21 | There is a step missing from the AWB adjustment procedurewhich puts the DDS display on the screen. | ||
Sony | CCDTR700 | COLORS ARE CHANGING / ZERO OUT DATA, PAGE "F" ADD 6B; WAS F1 | After comparing data with a working unit, found address 6B ofpage F to be F1 (AWB all tracking mode), changed data to 00 to restorethe normal mode of AWB operations. | ||
Sony | CCDTR700 | DIST/LOW AUDIO ON LEFT CHANNEL / REPL D519 ON THE JK-108 BD | Unit had very low and distorted audio on the left channel. | ||
Sony | CCDTR700 | DEAD / REPLACE F450 & F452 | Unit not powering on VTR/Camera. Found F450, F452 badcaused by drop of unit. Unit also has bend in cassette holder and brokenpart caused by impact of drop. | ||
Sony | CCDTR700 | CASSETTE HOLDER NOT CLOSING / REPLACE SLIDER (T) ASSY | Cassette holder is not closed and that's why the unit cannotaccept tape. Found Plate assy side broken caused by a drip. -SOLUTION :Replace (T) assy side. | ||
Sony | CCDTR70 | INDIVIDUAL MOTOR TESTING USING RM-95 | Models such as the CCDTR400 and CCDFX430 do not include themotor test on one of the service procedures, ex, capstan forward andreverse drum forward and reverse etc. | ||
Sony | CCDTR70 | NO COLOR ON RECORD OR PLAYBACK / REPLACE X201 | Camera had no color through the monitor, but pix in EVF wasOK. Discovered frequency of VXO 40 Hz lower. | ||
Sony | CCDTR70 | UNIT PLAYS WITH NO TAPE INSIDE / RPL PS500 | Unit goes into play with no tape inside also does not sensereel rotation. Found PS500 open | ||
Sony | CCDTR700 | INT. LOADING AND FUNCTIONS / RESOLDER IC 501 ON VS-99 BD. | Intermittent loading and function. | ||
Sony | CCDTR70 | WHEN VC-145 BOARD REPLACED IMAGER DOESN'T WORK/REVERSE CN701 | Imager stops working after board is replaced. | ||
Sony | CCDTR70 | NO CHROMA CAMERA E TO E - L605/VC BOARD | No chroma camera video Found that L605 was not passing the chroma signal. | ||
Sony | CCDTR70 | NO EVF PIX / MISSING DATA PAGE "D", ADDRESS B0 TO BB | No EVF pix. |