Dicas Reparação




Modelo - Chassis


Pesquisa: Enviar Dica Resolvida
Resultados 81391
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonySTRAV500
UNIDENTIFIED COMPONENTS FOUND IN UNIT Unit was found to contain a 1SS155 diode in this unitin the location of resistor R-358. There is no documentation shown tosupport this change.
SonyCFD460
UNIT IS LOCKED UP Unit would not read TOC. Moving the connector makes the unitfunction, (technician in Burbank) found the problem.
SonyCFS1020
WRONG PART NUMBER LISTED IN MANUAL Service manual for this unit lists motor as part number1-541-231-00. This motor is too big and interferes with cassette dooroperation.
SonyBM146
ERROR IN SERVICE MANUAL It has come to my attention that there is a error in theBM-146 service manual. PM-901 should be part number 1-454-194-00 andPM-903 should be part number 1-454-069-00. This problem was brought to myattention by my dealer in Pittsburgh and again by Overl
SonyDTX10
CASSETTE DOESN'T LOAD INTO UNIT, LOADING GEARS BROKEN Unit had broken gears (ref. 106-108).
SonyCDPH300
MISSING P/N FOR REF.905 CONNECTOR IN S/M The connector (ref.905) shown on page 15 of the S/M does nothave a part number listed. This connector connects between the Main BdCN201 and the Display Bd CN401. This has been visually verified.
SonySLV70HF
NO OUTPUT WHEN USING TUNER No output when using tuner. Channel change, tuning preset,bar-graph and band switching is ok. IF-301/pin 12 DET OUT signal is pre-sent but CN-302/pin 5 TU VIDEO OUT signal isn't present.
SonyCCDTR4
WRONG PART NUMBER IC-610 "VC-84" BOARD IC-610 IC listed as part number 8-752-335-65 is incorrect.
SonyMDP333
MECHANISM JARRED OUT OF PLACE DURING SHIPPING We are seeing a number of MDPs with the mechanism jarred outof place (see FPR No. L2139). This has always been caused by rough hand-ling during shipment. Can changes be made to the box to reduce this? -HQ COMMENTS: We are aware of this problem and hav
SonyBMC550
TROUBLESHOOTING THE CLOG DETECTION CIRCUIT Since the clog detection circuit is on for only about 200milliseconds, after a record pause it can be difficult to troubleshoot.Even if playback a known good tape to troubleshoot the voltages and wave-forms needed are not on the schematic.
SonyCCDF401
CAPSTAN MOTOR WILL NOT OPERATE IN RECORD, PLAYBACK OR EJECT In Play, Record and Eject modes the capstan would not turn.In FF or REW, F Search or R Search it would turn slower than normal andIC-504 on the SS-136 board would grow warm.
SonySTRGX67ES
NOISE IN REAR SURROUND CHANNEL WHEN NO SIGNAL PRESENT The rear surround channel has a high frequency hiss presentwhich is most noticeable with the master volume turned up to at least 50%,the rear channel level at 0dB and no signal source present (ie. betweentracks on a CD). There is also a noticeable buzz
SonySTRAV1070X
NOISE IN REAR SURROUND CHANNEL WHEN NO SIGNAL PRESENT The rear surround channel has a high frequency hiss presentwhich is most noticeable with the master volume turned up to at least 50%,the rear channel level at 0dB and no signal source present (ie. betweentracks on a CD). There is also a noticeable buzz
SonySTRAV970X
NOISE IN REAR SURROUND CHANNEL WHEN NO SIGNAL PRESENT The rear surround channel has a high frequency hiss presentwhich is most noticeable with the master volume turned up to at least 50%,the rear channel level at 0dB and no signal source present (ie. betweentracks on a CD). There is also a noticeable buzz
SonyKV19TS20
WILL NOT POWER ON WITH REMOTE CONTROL, REMOVE SOLDER BRIDGE Will not power ON with remote control. Everything else worksnormally. IC-101 and IC-102 had been replaced. Found IC-101 (pin 5SIRCS) at 2.8Vdc, when no pulses present.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads