SintomaCausaSoluçãoPor:
SonyMDP333
INT. MAY NOT WORK - REPLACED REF # 167 P/N 1-574-648-11 Unit has a very intermittent problem. It may work fine for several days and then not work at all. The flex cable to the optical unit may develop cracks that are hard to see. Pushing on the cable with a CD in the unit whil
SonyMDP333
INSTRUCTON TRANSLATION NEEDED. This instruction sheet supplied with kit is in Japanese. HQ COMMENTS: This sheet states that the belt and pulley should bechanged in order to prevent slipping.Remove the old pulley and press the new pulley onto the motors shaft.Adjust for a height of 7.
SonyMDP333
NO SPINDLE ROTATION The unit would focus, but would not rotate spindle. Inoticed a DC level change at pin 6 of IC202 and none at pin 7.
SonyMDP333
SLED MOTOR KEEP RUNNING MOVING THE FOP INSIDE Sled keeps running as soon as power on. Check the voltage #1(IC102) 15V, #3 (IC103) 8V and #18 19 (IC101)4V. Which shows IC102 isdefective.
SonyMDP333
3" DISC SLIPS OUT OF SLOT: REPLACE CD SHEET 3-735-039-03 The 3 disc slips out of the table. These discs are beveledon the edge and when the drawer goes in and stops, the disc slips forwardslightly. When the unit tries to chuch, the disc is off center and aremarked. There were several different manufacturer
SonyMDP333
NOISY VID/AUD AT END OF DISC: FOP FLEX CABLE 157464811 (168) On the twelve inch disc, the unit will skip and exhibit bothvideo and audio noise only at the end of the disc.
SonyMDP333
NO COLOR WHEN USING A MPU F100 FRAME GENERATOR: ADJUST CV601 The customer loses color on MPU F100. The color looked fineon the monitor, but it would not lock up on vectorscope.
SonyMDP333
LOOSE OPTICAL BLOCK We have been receiving reports of the optical block and trayof the MDP-333 shaking out of position during shipping. Some units areexchanged and some are repaired by replacing the broken parts. -SUGGESTION: This problem may be solved by removing the AC p
SonyMDP333
MECHANISM JARRED OUT OF PLACE DURING SHIPPING We are seeing a number of MDPs with the mechanism jarred outof place (see FPR No. L2139). This has always been caused by rough hand-ling during shipment. Can changes be made to the box to reduce this? -HQ COMMENTS: We are aware of this problem and hav
SonyMDP333
ELECTRICAL ADJUSTMENT CORRECTION (2-7-3 AND 2-7-4) In MDP-333 Supplement No. 1 on page 35 sections 2-7-3 and2-7-4 are incorrect. It Appears test points and adjustment points areincorrect. -HQ COMMENTS: The correct adjustment element in Section 2-7-3 is RV-154instead of RV104. The measuring point in Se
SonyMDP333
WILL NOT PLAY LD - CD IS OK Above unit did not lock up to LDs but plays CDs ok. Unitappeared to be not able to achieve proper speed. Also noticed unit wasn'table to input horizontal sync into sys control. Spindle motor would speedup to a point where RF was visible at TP momentar
SonyMDP333
NO OPERATION No display/spindle motor spinning counter-clockwise. Alsoapplies to serial number 816851.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.