Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | CFD510 | CD SKIPS WHEN JARRED: RESOLDER THE RF SHIELD TO CD BD | Intermittent audio. CD shuts off when jarred. | ||
Sony | CFD30 | DIFFICULT REMOVAL/REINSTALLATION OF CD CHASSIS | CD chassis difficult to remove and reinstall. This can breakthe function switch & am/fm switch. | ||
Sony | CFD21 | CD/NO SPIN -INSTALL SCREW P/N 7-685-648-79 | When a CD is installed, it rubs against the chassis. | ||
Sony | CFD12 | CD LID DOESN'T MATCH HOLDER, MAGNET: CHECK SUPP #1 FOR P/N | The CD lids that come when you order ref 111 X33671331,holder CD assy will not work with the part above, holder magnets. | ||
Sony | CFD10/12 | INCORRECT PART NUMBER FOR OPTICS: CHECK CORRECTION #1 | The part number listed for the optic device is incorrect.The part number listed is 8-548-137-11 for model CFD12. This info is onpage 37, Ref 405. For model CFD10 this info is on pg 64 Ref 405.SOLUTION: The correct part number for the optic device is 8 | ||
Sony | CFD10 | NO AC POWER: REPLACE INLET JACK P/N 1-540-009-11 | Switch inside inlet jack is defective. The switch gets stuckin the battery power position and will not accept the power cord. | ||
Sony | SLVR50C | SMEARY RED ON SELF RECORDING / DL301 | Smeary red on self recording try to adj RV302 and RV303 onYC93 BDboard but still did not correct the problem. | ||
Sony | SLV770HF | DOES NOT AUTOTRACK | Autotracking does not work. Found no RF envelope on pin60 of IC203.Shield of R/P amp had sharp pin which shorted some traces on RV-33 board. | ||
Sony | SLV720HF | UNIT RECORDS STATIC ON HI FI TRACK | When recording on line in audio, steady tone, the audiosounded fine but when playuing back what was recorded, there was staticpresent. | ||
Sony | SLV620HF | STOPS AFTER PUSH PLAY | No pulse at micro, stops after push play reads, L-01 abnormalT reel rotation) | ||
Sony | SLV620HF | LINE ACROSS MIDDLE OF PICTURE | When playback in EP mode picture is ok but will be distortedwhen it playsback in SP mode. -SOLUTION : Replaced upper drum restored normal operation. | ||
Sony | SLV585HF | TAPE GUIDE FALLS OUT | Retaining pin comes out of tape guide, cuaisng guide to fallout of unit. | ||
Sony | SLV585HF | LI SIGNAL NOT BEING DISPLAYED | Signal input of LI is not displaying -SOLUTION :IC102 is bad because it does not electronically switch.Replaced this IC restored normal operation. | ||
Sony | SLV20HF | UNIT WON'T EJECT | When pressing eject, the tape guides would come to the homepostion but the basket wouldn't come up. | ||
Sony | EVS700U | WHITE LINEIN PICTURE ON PB | Noise is generated in video on playback. |