Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | XRU880 | NO AUDIO (FOUND C306 AND C308 HAD LEAKED) | No audio from tape deck. C306/308 standard electrolyticcapacitors leaked onto EQ board. Traces aaround C306 were corroded andphysically lifted off the board. Electrolyte seeped through feedthroughs and stained the mechanism. All feed through are blac | ||
Sony | XRU880 | INSUFFICIENT QTY. OF PARTS IN CAP. KIT (BULLETIN # CAR354) | Capacitor kit X-337-022-11 in the service bulletin car 354indicates that a parts kit contains all of the electrolytic capacitors forrepairing the problem. The capacitor kit came with only 1 capacitor. | ||
Sony | XRU880 | DISTORTION, NO AUDIO, MECH MALFUNCTION, OR NO OPERATION | The above mentioned problems may be caused by leakage of oneor more of the electrolytic capacitors. | ||
Sony | XRU880 | DEAD UNIT (REPLACED Q504 AND D513) | Unit was dead. Master control IC was on but would not powerup unit (pin 5 stayed low). Bus On pin 38 would pulse low 3 times whenunit was powered up. Data and clock lines would show initial activity. | ||
Sony | XRU880 | POP IN AUDIO WHEN BUTTONS PRESSED | Audio popped each time a button was pressed on the faceplate that activates the mute transistors such as Seek +/-, Mau. +/-.Scoping the outputs on DC range showed a DC offset ranging from 100mV toas much as 900mV. Pop occured because mute transistors tak | ||
Sony | XRU880 | REFERENCE NUMBER CORRECTION (REF. 36 AND REF. 37) | Ref. #37 in exploded view is listed with part number for RCAjack and vice versa for ref #36. So when you order ref. #37 you will getref #36 part which could get confusing. | ||
Sony | XRU880 | CD CUSTOM FILE FEATURE INCOMPATABILITY XR-U880/CDX-U70 | Customer submitted unit with complaint Will not go into CDfile function but custom file works with radio. Tested unit andconfirmed problem. Subbed an XR-U770 with cust. CDX-U70 and found no CDfile functions again. Subbed a CDX-U300 into system and o | ||
Sony | XRU880 | NO OPERATION; RESET ONLY (REPLACE D511, P/N 8-719-977-07) | When power was applied to unit, reset was noted but, no otheroperation was possible. Since I was already familar with the Zener diodeson data and clock lines that either leak or are shorted, I checked D513and D514. These were OK. On this model there | ||
Sony | XRU880 | REPLACEMENT KEYSWITCH DIFFERENT FROM ORIGINAL | Replaced switch with one from diagnostic board. -HQ COMMENTS: This problem was also reported on the XR-U770. NPCchecked with Tokyo and found that the part number in the manual iscorrect, but that the switch vendor supplied the wrong switches. NPC hasp | ||
Sony | XRU880 | AMP REMOTE STAYS ON WITH POWER OFF | Customer states that power amp stays on even when unit is off. |