SonyXRU550
EXTENSION CABLE FOR REPAIRING DISPLAY MCB (J-2502-009-3) It may be difficult to repair the display MCB without using anextension cable.
SonyXRU550
LOSES PRESETS, CLOCK RESETS TO 1:00 (REPLACE RESET IC101) The unit's presets are lost, and the clock resets to 1:00.
SonyXRU550
PART # CORRECTION, IC702 (CORRECT # IS 8-759-509-91) The part number in the service manual on page 71 for IC702 isincorrect. The manual lists the same number and description for IC701 andIC702, but they are two different ICs.
SonyXRU550
UNIT INOPERATIVE (REPLACE R569, 2.2 K, P/N 1-216-057-00) The unit did not have any power, it was inoperative.
SonyXRU550
TONE CONTROLS & CLOCK RESET WHILE IGITION IS OFF (Q-518 BAD) A customer complained that whenever he cut off ignition, theclock resets to 1:00 and the volume, balance, and tone settings reset.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.