Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | TCW233 | ERRORS IN HI-FI SERVICE BULLETIN NO. 82 | There are several mistakes in this S/B. First, the originalmotor for this unit (X-3595-921-1) is still available, thus it is notnecessary to use the X-3595-923-1 motor that is listed. By the way, the-923 motor is also the one listed in the S/M Correcti | ||
Sony | TCW233 | NO OUTPUT FROM A DECK - DISPLAY FLUCTUATES - NOT IN PLAY | This unit had two unrelated problems. No output from A deckwas traced to a bad A-B switching IC. The display problem was still pre-sent. If a tape was played, then STOP pushed, the meter would show anindication like an oscillation in both channels. F | ||
Sony | TCW233 | REC MUTE ACTIVATED CONTINUOUSLY | REC MUTE would not release in record mode. I found that Q305emitter input was from a line regulated by D506, and the base input indir-ectly from a line regulated by D505. |