Modelo - Chassis TCFX2


Pesquisa: TCFX2 Enviar Dica Resolvida
Resultados 8
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyTCFX211
CAPSTAN RETAINING RING
SonyTCFX211
DISTORTED AUDIO - REPLACED T/U REEL Distorted audo sound when playback after record. Problemusually happens at the end of the tape.
SonyTCFX2
UNIT WOULD NOT PLAY - FOUND FORWARD LEVER STICKING The forward lever was very tight because the old grease wasdry and sticky.
SonyTCFX210
P/N FOR HEAD WIRES We need the part numbers for the shield wires with plugs forthe REC/PB head (CNJ301) and erase head (CN302). -HQ COMMENTS: We do not have a service part of the shield wire withconnector. We have shield wire which is 10m long.1) 4 conductor wire with br
SonyTCFX25
IMPROPER OPERATION WITH TAPE When using BASF Professional II, C-90 cassettes, the tapewould skew upwards just past the leader splice, ruining the tape. Thecustomer claimed all other brands worked fine, including the newlydesigned BASF Professional II.
SonyTCFX2
STUCK LEVER Audio line output muted in all modes. The problem wascaused by a stuck lever assy, which is used to operate the mutingmicro-switch, located on the lower right corner of the rear of the tapetransport. While attempting to disassemble, the lever suddenly
SonyTCFX22
IDLER WHEEL BINDING Playback was very slow.
SonyTCFX22
BEND IN SLIDER NEEDED Transport fails to have take-up in playback or record mode.Transport is excessively noisy and will not engage into FF smoothly.All of this can be caused by slider (355) being bent causing FF lever(305) to have incorrect timing in conjunction with take-up


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.