SintomaCausaSoluçãoPor:
SonyTAM50
NO MECH MOTION RESOLDER MOTOR M1 Mech had no motion. I replaced S101 and did not solve theproblem. I found that the M1 wire was loose or cold soldered at themotor.
SonyTAM50
INTERMITTENT POWER - REPLACE MOTOR M1, P/N 1-541-705-11 When power is first applied, motor will not do an initial tapereset. This also causes unit to appear to have no power. This is causedby a defective motor (M1). The following internal defects were found inM1: Rusty laminated armature, defective armatu
SonyTAM50
LOW AUDIO - REPLACE IC5, P/N 8-759-903-86 Low audio is heard when messages are played back. Tracedaudio signal to IC5 and found the output to be producing a low signal.
SonyTAM50
SERVICE MANUAL HAS BEEN REVISED The Service Manual has been revised. However the new manualhas not been released as yet. -HQ COMMENTS: Tokyo will soon issue the revised manual. Until revisedU.S. model is issued, use Canadian service manual p/n 9-955-536-21.The following changes were i
SonyTAM50
NO OGM ACTIVIATION - REPLACE RY1, P/N 1-515-693-11 Unit rings but OGM will not activate. Voltage around Q2checks out OK, found Q2 turning on but RY1 was not closing. Replacing RY1fixes this problem.
SonyTAM50
NO OGM OUT - REPLACE R302, P/N 1-247-895-11 When playing OGM, audio is fine out of speaker, but not makingit out onto telephone line. Checked audio on isolation transformer T1.Found weak signal. Checked signal between IC4 pin 7 and isolationtransformer T1 (OGM audio path out), found R302 open.
SonyTAM50
DROPS LINE IMMEDIATELY AFTER OGM ACTIVATION - REPLACE C4 After unit receives select amount of rings, OGM activates thenimmediately drops telephone line. Found Bell/OGM int. line not holdinglow after OGM activation. PH4 is not turning on. Checked voltages on pin1 & 2 Ph4 during OGM activation. Found pin 1 o
SonyTAM50
PART NUMBER CORRECTION: KEYBOARD SWITCHES The part number for keyboard switches: SW1 to SW8, and SW15 isincorrectly listed in the service manualas 1-554-937-11.
SonyTAM50
WILL NOT ANSWER INCOMING CALLS
SonyTAM50
WILL NOT ANSWER INCOMING CALLS Customer complains of unit not answering incoming calls. Unitworks fine in shop. Most of these that we have seen are when the customerlives in a smaller community or rural area. These answering machines seemto have a problem detecting the ring on some
SonyTAM50
DROPS THE LINE After answering ring signal, unit would drop the line duringOGM playback. After visual inspection, R-5 and R-7 were found to beshorted together. Also pertains to serial number 180783.
SonyTAM50
LOW AUDIO Low audio during playback of any function. This was caused byCN-A leads being shorted. Also pertains to serial number 72887.
SonyTAM50
AVAILABILITY OF AC-T122 AC ADAPTOR Previously the AC-T122 AC Adaptor used in this unit was notavailable, and was subbed at KCPS with a AC-T120. However the AC-T120 is a200 mA adaptor, while the AC-T122 is a 300 mA Adaptor. Therefore theAC-T120 will not operate the TAM-50. Therefore as of
SonyTAM50
UNIT NOT ANNOUNCING TIME Unit is not announcing time, it beeps. There is no activityon IC-10/pins 34 and 36. IC-10 (the Time IC ), and IC-3 (the micro) wereboth replaced. Problem still persists. All other functions seem towork ok. -HQ COMMENTS: Please check the following pi
SonyTAM50
LOW OGM PLAYBACK TO CALLER - ICM CUTS OFF When the TAM answers an incoming call, the OGM will be playedout the line at a low volume level and the ICM will be cut off inter-mittently. This is caused by ZD-1 leaking and allowing the line currentto drop below the minimum level required to hold the


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.