Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | TAAV501 | UNIT ON PROTECT - Q700 LEAKY, REPLACED | Unit goes to protect mode if AC over 120V. | ||
Sony | TAAV501 | UNIT GOES INTO PROTECT - C700 FAULTY P/N 1-161-494-00 | Unit goes into protection immediately after power up. | ||
Sony | TAAV501 | NO AUDIO/INTERMITTENT RIGHT LEFT | No output on right channel. Noticed audio on tone input line(R) (CN-513 pin 3) was shorted to ground. Found that metal shielding onfront panel beneath volume control connector (CN-402) was shortingconnector pins. |