Modelo - Chassis STRGX60ES


Pesquisa: STRGX60ES Enviar Dica Resolvida
Resultados 4
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonySTRGX60ES
INTERMITTENT PROTECTOR LIGHT Protector light illuminates after a few seconds of play orafter unit is moved.
SonySTRGX60ES
BIAS ADJUSMENT PROCEDURE IS INCORRECT Noticed the bias adjustment was not correct in the Servicemanual. In the manual, it called to measure across R710(LF) & R760(RT).I believe you should measure from the emittrs of Q-704 & Q-703 for theleft channel and Q-754 and Q-755 on the right channel.
SonySTRGX60ES
DISTORTION ON ONE CHANNEL OR HISSING EITHER LEFT OR RIGHT Distortion on either left or right channel. This particularcustomer called it hissing sound. Acting up when it gets hot. Note: Haveencountered several of these models with the same problem. Factory hasnot soldered the output transistors correctly to
SonySTRGX60ES
BROKEN POWER SUPPLY BOARD - DEAD UNIT This is the third unit I have seen with damage to the powersupply board. All three were dead out of the box. The cracks are locatednear transformer T-901. It appears that T-901 is just heavy enough tooverstress the board should the unit be dropped in


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads