Dicas Reparação




Modelo - Chassis STRAV650


Pesquisa: STRAV650 Enviar Dica Resolvida
Resultados 3
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonySTRAV650
DEAD SET Unit would not respond to system on switch, pins 18-29 wereall high. Data could not be entered from key matrix. Changed IC-301 unitstill would not come on. Note all I/O data and clock lines were activefrom all three micros.
SonySTRAV650
SERVICE MANUAL PART NUMBER ERROR - MAIN PCB When above part number is received, it will not fit. Theconnector plugs are different. Investigation revealed that theA-4410-262-A board fits the STR-AV580/590. It was listed in the STR-AV67/650 manual. I found that the correct part number for the ma
SonySTRAV650
UNIT DEAD Unit dead, could not power up. Found no data on clock line toIC302 due to leaky 6800PF capacitor (factory installed) on clock line toIC302 on display board.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads