SonySTRAV570X
PROTECT ON - RESOLDERED GROUNDS ON MAIN BOARD Someone had installed a larger than normal screw to hold theheatsink to the chassis. This caused a poor connection of the board toground.
SonySTRAV570X
CONTINUED PROBLEMS AFTER PERFORMING S/B HFP227 After performing S/B HFP227, the customer returns the unitand complains that it's doing strange things again. There is a large areaof the main PCB that is only grounded by the heat sink through pressurepoints to the board. By connecting a DVM between cha
SonySTRAV570X
POOR RECEPTION ON TUNER - R703, Q701 FAULTY Unit turns on but no radio reception. I found shorted Q701,and damaged R703. Tuner board lost +13 B+, cannot tune, no radio.
SonySTRAV570X
HEAVY STATIC, SOUND IS NOT CLEAR - C418 SHORTED 1-124-478-11 The unit had audio but heavy distortion on both channels. Ithought the problem was in the output section since the unit would go intoP mode when the volume increased slightly.
SonySTRAV570X
FOLLOW UP ON GROUND PROBLEM ON DISPLAY BOARD After close scrutiny of the display board and schematic, Ifound a discrepency. The schematic shows constant ground plane on displayboard, however, the board layout shows isolated ground plane for CPUIC301. Why is this so? After checking the board of th
SonySTRAV570X
VIBRATING NOISE AT HIGH VOLUME When volume is turned up with speakers off and withoutheadphones connected (unit under no load), the headphone jack vibratesmechanically and produces an audible vibrating noise.
SonySTRAV570X
RIGHT CHANNEL INTERMITTENT, DUE TO DEFECTIVE VOLUME CONTROL I have three dealer units with defective volume controls. Twoare with noise and one is distorted. Kansas City has not been able toprovide the control. These are new models.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.