SonySPPA60
INTEMITTENT OR NO TRANSMIT - REPLACE L512, P/N 1-402-757-11 Unit would only transmit sporadically. Tapping on board causedno transmit.
SonySPPA60
HANDSET TRANSMITS/RECEIVES INTERMITTENTLY OR NOT AT ALL Handset of models SPPA20, 40, 60 develop intermittenttransmit or receive problems. Tapping or soldering around transformersreveals problem by restoring operation. For transmit problems culpritappears to be L512, 3 occurrances last week.
SonySPPA60
MEMO RECORDING ONLY LASTS ONE MINUTE Customer complains that the MEMO recording only lasts oneminute, while the instruction manual states that the MEMO recording shouldlast to the end of the tape. -HQ COMMENTS: This is due to a software change in the micro. The microwas changed to resolve
SonySPPA60
NO TRANSMISS DISTANCE CUTS OUT AFTER ANWER OR CALL No transmission and cuts out right after answering orcalling. Neither handset nor base can transmit or receive.
SonySPPA60
STATIC AND VERY LOW VOLUME - REPLACE FILTER FT502 Handset has static and very low volume.
SonySPPA60
CORRECTION OF S/B/TEL 0089 Per Tokyo, the correct p# for the black antenna for SPPA60 is1-501-558-21. Please correct in the SDIS system and issue a s/bcorrection. -HQ COMMENTS: Thanks for the info. A new or revised bulletin will beissued.
SonySPPA60
NO HANDSET MIC - REPLACE IC503, P/N 8-759-089-92 Handset has no MIC. Traced audio from MIC on handset toIC503/pin 7 (Compressor/expander IC). When audio disappeared, found DCvoltage low on IC503/pin 7. Lifted pin and audio returned. IC503 wasshorted.
SonySPPA60
NO TALK - R6 MISSING IN BASE No receive coming in to the base. I was checking IC1 (signalProcessor) and it was functioning properly. I went through Q3 (IF amp)and found out R6 is missing in the circuit. No existing part was put inat factory.
SonySPPA60
ICM TIMING FAILURE - REPLACE IC015, P/N 8-759-089-93 Incoming message record time was less than 60 seconds. Ichecked the Vox circuit IC015 and the timing circuit. I noticed thatIC015 is cold soldered.
SonySPPA60
PINCH ROLLER JAMMED IN ENGAGED MODE. NO ATM FUNCTIONS. Mechanical deck assy intermittently jams. It locks up withpinch roller engaged. Once engaged, it will not release pinch roller. Unitcomes in with pinch roller engaged. The first time we apply power, thetape assemblies release the pinch roller and the mec
SonySPPA60
NO OGM RECORDED Unit acts like it is recording, displaying that it isrecording (counts for 16 secs) but does not playback any audio. IC11,IC12 and IC15 were replaced. We can see audio through capacitor C79, onpin 15 of IC11 but not on Pin 16 (input). -HQ COMMENTS: Th
SonySPPA60
NO POWER IN HANDSET - REPLACE D506, P/N 8-719-017-51. Handset came in with no power. Going to IC505, systemcontrol, I measured all the VCC and ground lines. Everything checkedout OK. Then, I went and measured some of the pins on IC505 and found pin#23 to be high. When shorted to ground the H/S would wor
SonySPPA60
VOX CUTTING OFF MEASAGES TOO EARLY-REMOVE SOLDER BRIDGE(R99) When answering machine would take the ICM, the VOX would cutthe messages off. Going to the Micro first, I found that when leaving amessage, the VOX Pin wasn't pulsing high and low like it should have been.Following it back, IC15/Pin 13 had audio going i
SonySPPA60
NO RING, NO INTERCOM OR AUDIO AT SPEAKER BASE-RESOLDER J301. No audio at OGM, ring, intercom, memo and play back. Imeasured the speaker resistance (32 ohms), but measured an open at basekeyboard. Found cold solder at base keyboard J301 connector and at speaker(SP601) wires.
SonySPPA60
NO POWER H.S. - REPLACE IC504, P/N 8-759-511-37. No power H.S. There was no voltage on pin 3 of the voltagedetect IC504. I noticed that IC504/pin 3 was cold soldered.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads