SonySPP75
FAILS TX FREQUENCY OFFSET - S/B PUBLISHED This model does not have a variable capacitor to trimthe crystal oscillator. Consumption of the part seems high. A possibletolerance problem exists. What tolerances should we expect of thispart, both in production and replacement categories? Two rep
SonySPP75
INADEQUATE CHARGING OF HANDSET BATTERY Units come in with complaint of short battery life, orincomplete charging. Traced cause to poor connections between solder padson mic board and charging terminals.
SonySPP75
NO CHARGE - RESOLDER D751. Unit will not charge. Found that D751 was cold solderedpreventing Handset from transmitting.
SonySPP75
RANGE DISTORTION - REPLACE L1, P/N 1-402-571-21 Distortion is heard when Handset is at minimum of 5 Feet frombase. Checked L1. Coil is opened.
SonySPP75
LOW MICROPHONE LEVEL ONTO TELEPHONE LINE. Found unit to have low microphone audio level out thetelephone line. Adjusted RV552 in the handset to increase the mic signalgoing into IC551.
SonySPP75
DISTORTED AUDIO - ADJUST RV52 IN BASE TO LOWER HANDSET AUDIO Found dial tone to be real loud in handset. Adjusted RV52 inthe base for more resistance to decrease the dial tone signal onto thehandset.
SonySPP75
NO TALK- ERROR BEEPS - REPLACE Q-551, P/N 8-729-821-27 When the talk button was pressed on the handset, the unitwould not scan through the channel LED's but LED 1 and 2 would blink alongwith five error beeps. The handset was not transmitting during the test.I found Q551 open which is the TX switch to supply
SonySPP75
RINGS, BUT WILL NOT CONNECT-REPLACE RY-301, P/N 1-515-773-11 I found the unit was able to ring, but it would not grab aline. Q302 was turning on, but the line relay RY-301 would not kick.
SonySPP75
NO POWER LED - REFLOW R-260 No power LED. Unit worked fine, but the power LED did notlight. I found R260 cold soldered.
SonySPP75
HANDSET TRANSMIT FREQUENCY HIGH OR LOW - REPLACE X-651 X-651 is defective preventing the adjustment of the handsettransmit frequency. The TX frequency can be either high or low. I haveseen many of both circumstances. Also applies to serial number 1127339.
SonySPP75
NO BASE TRANSMIT - DEFECTIVE IC-151 LOADING B+ LINE Found base unable to transmit. Checked Q-253 collector andfound 1V. Lifted pin 17 of IC-151 (VCC) and checked Q-253 again and foundvoltage to return to 3V.
SonySPP75
NO HANDSET TRANSMIT - DEFECTIVE IC-651 LOADING B+ LINE Found handset unable to transmit. Checked voltage at pin 4 ofIC-652 and found 1V. Lifted pin 17 of IC-651 (VCC) and checked pin 4 ofIC-652 again and found voltage to return to 3V. Also applies to serialnumber 1404397.
SonySPP75
NO HANDSET TRANSMIT Handset was not putting out any transmit signal. L-553 waspopped through the board and not allowing for oscillation.
SonySPP75
UNIT WILL NOT DIAL *, 0, OR #, 7, 8, 9 IN TONE Will not dial *, 0, or # in tone because the trace between pin6 of IC-351 and pin 20 of IC-201 is open (under IC-351). Will not dial 7,8 or 9 in tone because the trace between pin 3 of IC-351 and pin 19 ofIC-201 is open (under IC-351). Open traces appe
SonySPP75
NO VOLUME CONTROL Found unit not able to change the volume of the handsetspeaker. Checked pin 3 of IC-701 (Volume Pin) was always low. CheckedR-720 and found it missing. R720 supplies the high for IC-701/pin3. Alsopertains to serial number 1216540.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.