Dicas Reparação




Modelo - Chassis SLV50


Pesquisa: SLV50 Enviar Dica Resolvida
Resultados 18
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonySLV50HF
ROLLER ASSEMBLY CREASES T-160 TAPES T-160 tape creases on the exit guide roller.
SonySLV50
BLUE SCREEN Intermittent blue screen on Playback of pre or self-recordedtapes. Due to complexity of the CTL signal process in unit, when failureof CTL pulse is detected, IC-503 switches off the CTL ckt. making it diff-icult to detect problem area when following CTL
SonySLV50HF
BLUE SCREEN ON WEAK STATIONS A blue screen is seen or recorded when a weak station isreceived.
SonySLV50
RF MODULATOR AUDIO SIGNAL PATH IN SLV-50 Since the SLV-50 does not have the HF-6 board (for Hi-Fiaudio) to provide audio to the RF modulator (CN-553) a 6.8K Ohm resistor(chip component) is connected between pins 11 and 8 of CN-571 on theMA-27 board. This information is not shown in the service
SonySLV50
HEAD DRUM REPLACEMENT PART This part is being substituted by part number 8-848-518-01.When this substitute part is installed, tapes recorded on the machine havea rainbow noise pattern at the beginning of the recording evidence thatthe flying erase head is not working. When the or
SonySLV50
INTERMITTENTLY WILL EJECT TAPES VCR will intermittently fail to eject tapes. Eject buttonmust be pressed several times to eject tape.
SonySLV50
SERVICE BULLETIN NO. VID0122R1: IC-501 SUBSTITUTE Per bulletin VID0122R1, either IC substitution will work.Part number, 8-752-814-77, has a dealer cost of $28.91. Part number,8-752-815-32, has a dealer cost of $65.32. Both are in stock in KansasCity. -HQ COMMENTS: Thank you for the information.
SonySLV50
EXCESSIVE WOW Unit had excessive wow in EP mode. SP was OK. Measured fowardand back tension, foward(90), backward(40). Found other machines read 150on foward tension.
SonySLV50
IC-599 PART NUMBER CORRECTION Correct part number per semiconductor replacement handhook is8-759-910-84. -HQ COMMENTS: The correct part number is 8-759-910-84. See servicebulletin number VID0117.
SonySLV50
BLUE SCREEN OR BLANK SCREEN AFTER A FEW MINUTES After playing back a tape for a while, the TV screen willbecome blue if the monitor uptput is used, or blank if the line out isused. Found that IC-407 on the (MA-27) Board had no playback controloutput. Freeze spray would cause it to function for a whi
SonySLV50
VIDEO BLANKS WHEN DUBBING COPY GUARDED TAPES Customer says that the video blanks and the unit puts up ablue screen intermittantly when he dubs a copy-guarded tape. This occurswhen the video signal drops. Is there an adjustment for this? -HQ COMMENTS: There is no adjustment for this, adjusting ot
SonySLV50
LP-4 KIT INSTALLATION CAUSES IRREGULAR CAPSTAN OPERATION Capstan would intermittently not turn in loading-FF-REW modesand act sluggish also a constant audio warble in normal audio. Thisproblem appeared after installing LP-4 kit with update IC-501 on (MA-27)board.
SonySLV50
NO MEMORY BACKUP - MANUAL INCORRECT Unit had no memory backup. Found C-608 to be open. The partslist shows this as a 220mf. It should be a .22f/5.5v. Also the blockdiagram shows C-606 to be backup, which is not the case. C-606 is a .1ufnot .1f.
SonySLV50
NO OPERATION AFTER SOME TIME When the power switch is turned on, the unit works for awhile.After some time, no functions will operate. Turning power off and onwill cure this problem for awhile, but will occur again sometime later.
SonySLV50
PART NUMBER FOR CN-553 CONNECTOR CABLE I need the part number for the 5-pin conductor cable thatconnects the RF mod. to the (MA-27) board (CN-553). Would you please faxor call with this info?


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.