Dicas Reparação




Modelo - Chassis SL10


Pesquisa: SL10 Enviar Dica Resolvida
Resultados 16
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonySL100
NO POWER - NO DISPLAY REPLACE R-6 ON PS-96 BOARD No display and no power. No -29V from power supply.
SonySL10
NEW FRONT LOADING ASSEMBLY INSTALLED, DOOR DOES NOT WORK The teeth on the cassette door are too short for the newloading assembly. Do I have to put in a new door? -HQ COMMENTS: Yes, there was a production change and a new door underthe same part number will have the longer teeth and fit the new loadingassemb
SonySL100
CAPSTAN SPEED IS SLOW When I played back BII tape, sound is slow, and also pictureis distorted.
SonySL100
WON'T RECORD VIDEO Won't record video, audio record and audio/video PB OK.
SonySL100
NO FUNCTIONS, TAPE STUCK No functions, pause light on all the time, with power on capsand drum both running.
SonySL100
UNIT SHUTS DOWN When reel is turned by hand with original part waveform wasintermittent. With four new PC-101 -HQ COMMENTS: After replacing the PC101 (SP1201-22) on the RD-21 board,we have found no problem. I have found that the painted white dotindicate Pin 1 of PC1
SonySL100
WILL NOT ACCEPT TAPE Will not accept tape.
SonySL100
POOR VIDEO Unit displayed poor video. Looked like bad heads. (B) headmissing from envelope.
SonySL10
VERTICAL COLOR BARS, BAD SOUND, BAD VIDEO Very weak picture, vertical color bars and sound verydistorted. Found 9VDC on IC1 reading 6.5 volts.
SonySL10
WOW AND FLUTTER IN SOUND, PICTURE OK Wow and flutter, picture OK. Removed the tension assy andlightly sanded the supply reel assy. Note: This is the second unit. Didthe same thing to a SL-25, see FPR. H0402.
SonySL10
WILL NOT LOAD, DRUM SPINS VERY SLOWLY IC201 was blown. Replaced IC201, loading was very slow, thenjammed. Found solder between teeth on gear (D) (Ref 269, P98). Removedsolder and reassembled. Loading action was restored, but drum motor ranvery slow in play, and would run slowly even in s
SonySL10
EATS TAPE Eats tape.
SonySL10
EATS TAPE, INTERMITTENT LOSS OF FG Eats tapes. Capstan speed overruns, spilling tape.
SonySL10
SOLENOID PLUNGER The original part # 1-454-349-41 was subbed to 1-454-365-51.The new solenoid fit the unit, but the collar on the plunger would notclear the mounting pieces on the unit. The original plunger had nocollar. We need to have the plunger changed on this sub.
SonySL10
NEGATIVE PICTURE Negative picture and no sync on E-E and PB.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.