Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | MDP700 | CORRECT PART NUMBERS FOR WOODGRAIN SIDE PLATES | |||
Sony | RMP700E | INCOMPATIBLE PART - UPPER LID ASSEMBLY | Replacement part is physically different than original doorassembly. Hinge area, left and right on new replacement part hinge area,left and right on new replacement part has additional plastic which willnot allow replacement. Original door is open ende | ||
Sony | RMP700A | INCOMPATABLE PART - UPPER LID ASSEMBLY | Replacement part is physically different than original doorassembly. Hinge area, left and right on new replacement part has addi-tional plastic which will not allow replacement. Original door is openended on left and right hooks. The replacement part | ||
Sony | CCDSP7 | VIDEO ROLLS IN CAMERA MODE | Video rolls in viewfinder and monitor. | ||
Sony | MDP700 | DISC IS INTERMITTENTLY EJECTED | CD or LP intermittently ejects during or before play. | ||
Sony | MDP700 | WILL NOT PLAY CD'S | Unit will not play CDs but LDs play fine. | ||
Sony | RMP700E | REPLACEMENT LID DOES NOT FIT | Replacement lid will not fit because the hinges have beenchanged. -HQ COMMENTS: In order to prevent the lid from disengaging from theremote it's hinge was changed. In order to use this new lid a portion ofthe molded shaft must be cut away. Please see | ||
Sony | CDP790 | WON'T PLAY DISC | When putting in a disc, the laser wouldn't come up to read thedisc. | ||
Sony | KP7225 | SHUTDOWN, REPLACED C110 | Unit shuts down when you change channel, volume etc. TP-6812V has noise on it. Replaced C-110. -HQ COMMENTS: C-110 is main filter capacitor of high B+ standby voltage(for relay drive) from which low B+ standby voltages (5V, 12V) arederived (for RC cir | ||
Sony | MDP700 | PART NUMBERS FOR SERVO CHECKER CABLES | There are no part numbers available for the LD and CD checkercables in the service manuals. -HQ COMMENTS: Part number for the LD cable is J-6080-880-A. Part numberfor the CD checker cable is J-6080-922-A. Both parts are available in KC.The old servo c | ||
Sony | CDP707ESD | INTERMITTENT PLAYBACK | Customer said unit would intermittently skip and stop playing.Unit had been at authorized shop two times (FOP changed once). Testedunit with no evidence of problems. Upon pressing on IC-101 (RF IC) RFpattern distorted and dropped out. As only pressing | ||
Sony | CCDSP7 | NO VTR FUNCTIONS | Found no VTR functions after loading of tape. Unit doeseject and works fine in camera mode. Unit acts like it is in OFFposition. | ||
Sony | CCDSP7 | MOTOR NOISE PICKED UP BY MICROPHONE. | Customer complaint of motor noise in audio. Factory modon service bulletin #122 already installed. | ||
Sony | CDP701ES | APC ADJUSTMENT PROCEDURE | The attached FPR from 10/23/85 (not in computer) indicatesthat it would be issued on how to adjust the laser output but I cannotfind any such Service Bulletin or Supplement etc. Was this ever issued?What is the adjustment procedure? -HQ COMMENTS: When | ||
Sony | CCDSP7 | LINES IN PLAYBACK | Herring Bone in playback after a couple of minutes. Problemis present if self-recorded or pre-recorded tape used. |