Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | MTL10 | REPACK KIT | Approx. 3 months after installation of MTL repack kit(T-998-025-81), IC became defective. Only way to get new IC is to consumeentire new repack kit. | ||
Sony | MTL10 | DETECTION SENSITIVITY ADJUSTMENT MISADJUSTED | Unit would not line up properly to load the first cassette. | ||
Sony | MTL10 | CAM GEAR OUT OF POSITION | Several units did not work out of the box. The problem isthat the main cam gear is not properly positioned. Repositioning the camresolves the problem. -HQ COMMENTS: The main cam gear being out of position may have beencaused by some irregular cassette | ||
Sony | MTL10 | LOADING MECHANISM JAMS | After a month or two, the loading lever does not enter intothe groove on the cam gear. This in turn causes the loading mechanism tojam and subsequent inoperation of the unit. -HQ COMMENTS: Check for slippage between gear A (Item No. 3), O-ring(Item No. | ||
Sony | MTL10 | SLIDE PLATE STICKS | Intermittently the cass. will not retrack back from themechanism to the cass. slider. After unit is unjammed, it will work upto 3 hrs. before failing again. | ||
Sony | MTL10B | DEFECTIVE Q511 | All functions inoperative. Unit had been worked on by dealerand microprocessor had been changed (IC502). Found that there were nokey scan pulses to Pins 30/31/32 and IC502. |