Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | MDS501 | BROKEN DISPLAY PCB - REPLACED BROKEN DISPLAY BOARD | Board broken in half during shipping. The ams knob does notuse a retainer nut on the outside of the front panel. If pressure isapplied to the knob there is nothing to prevent damage to pc board. | ||
Sony | MDS501 | NO RECORD/ INTERM EJECT - REPLACED IC110 | Unit would not play back after recording and when TOC editwas finished it would not eject. | ||
Sony | MDS501 | EJECTS DISCS - REPLACED MISSHAPEN RECORD HEAD HR901 | When you insert a disc unit attempts to read and ejects.Found record head on two units to be bent back preventing disc fromcompletely loading. | ||
Sony | MDS501 | AFTER RECORDING UNIT WILL ERASE ENTIRE DISC - REPL IC101,110 | Unit worked fine all measurements were good, but whenrecording it would record informatin on head but after rec unit woulderase entire disc. Noticed pre 94 IC's in unit. | ||
Sony | MDS501 | NO SCROLL FUNCTION - IC301 DISPLAY DRIVER | Song titles would not scroll across display. Replaced IC111and IC103, no change in symptom. -SOLUTION : Replaced IC301 display driver restored operation. | ||
Sony | MDS501 | DIGITAL NOISE IN PLAYBACK AND RECORD - REPL IC101 | Noisey digital playback. Recorded playback was even noisier. |