Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | MDP200 | CHUCK PLATE ASSEMBLY - REPLACEMENT PART NUMBER | When ordering X-3720-326-1, it subs to 9-9109-993-8 (ReplaceComponent Part). | ||
Sony | MDP200 | NO CLV LOCK ON CD - LD OK | CD would not lock, no play but LD is ok. Authorized servicerreplaced CD spindle motor. I looked in the computer - SDIS and read FPRnumber L1639. It said magnet was too weak for CD. I didn't believe thatchanging the magnet would solve the problem but | ||
Sony | MDP200 | PART NUMBERS FOR SERVO CHECKER CABLES | There are no part numbers for the LD and CD checker cables inthe service manual. -HQ COMMENTS: Part number for the LD cable is J-6080-880-A. Part numberfor the CD checker cable is J-6080-922-A. Both parts are available in KC.The jigs are no longer nee | ||
Sony | MDP200 | NO CLV LOCK ON CD - NO PLAY - LD OK | Unit plays LD but not CD. Looked like CLV servo problem. | ||
Sony | MDP200 | RADIO FREQUENCY INTERFERENCE | Unit had herringbone type interference caused by A.M. radiostation 850 K.C. WHDH Needham, Massachusetts (approximately 1 1/2 milesaway). Problem showed up in both video and R.F. out. The interference isA.C. line related. | ||
Sony | MDP200 | LD PICTURE DISTORTED AND CD DOES NOT PLAY | 1. Distorted LD picture. 2. CD does not play. | ||
Sony | MDP200 | 3.5 INCH DISC SPUTTERING | Unit does not play 3.5 inch disc instead there is a sputteringsound from it. | ||
Sony | MDP200 | DRAWER ONLY OPENS TO 12 INCH LD POSITION | Drawer will not open to CD position. IC-004/Pin 23 alwayslow. IC-009/Pin 10 toggles correctly with 12 inch disc in or out.IC-009/Pin 13 always low, and shorted to ground. |