Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | KV32XBR95S | SPEAKER BOX COMPLETE PART NUMBER IS WRONG, SEE BELOW | Speaker box reference number 93, and 86, are shown in the SMas containing the speaker box and related components. When ordered onlythe speaker box is received. The part number for the complete speakerbox is needed. -HQ COMMENTS: The part number for | ||
Sony | KV32XBR95S | NO CHANNEL CAPTION IN AUX MODE, NORMAL | In the aux mode the customer can not use the Channel Captionfeature (example channel 4 as NBC). When they bring up the menu thescreen turns gray. There is no mention of this in the Owners Manual. -HQ COMMENTS: This is normal operation, the Channel Cap | ||
Sony | KV32XBR95S | SET SHUTS DOWN IMMEDIATELY AFTER TURN ON: REPLACED IC-1402 | The set will shut down immediately after turned on. | ||
Sony | KV32XBR95S | PIN CUSHION DISTORTION, REPLACED Q-506 | Picture was bowed in on the sides. | ||
Sony | KV32XBR95S | INOPERATIVE SET, REPLACED IC-1401 | Relay would not click when power button is pushed. It wouldclick when unit is plugged into AC. Unplugged connector G-5 on G boardand power switch would work. | ||
Sony | KV32XBR95S | NO PICTURE IN TV MODE, RESOLDERED BOTH Q-605, AND D-655 | No picture in TV mode, the video mode was ok but missing twoinches at the bottom of screen. Found all B+ voltages low causingincorrect voltage at tuner and vertical. | ||
Sony | KV32XBR95S | INTERMITTENT COLOR, RESOLDERED IC-1204 | Color would fade to black and white after turn on. | ||
Sony | KV32XBR95S | INTERMITTENT COLOR, RESOLDERED P4 BOARD | Color would fade to black and white after turn on. | ||
Sony | KV32XBR95S | NO STEREO ON SOME CABLE CHANNELS, TRY THE STEREO ADJUSTMENTS | ASC has customer's unit that will not receive stereo on theabove listed channels. Customer's SLV-757UC receives the same channelsok. Servicer checked dealer's KV-32XBR95 and has the same problem. Needassistance to resolve problem. Set works ok on air | ||
Sony | KV32XBR95S | NO CHANNEL NUMBERS IN PIP INDEX MODE, ADJ T-3001, T-3002 | When in PIP index mode either 8 or 16 the channel numbers aremissing. Video is OK. On main picture channel numbers are OK. Now havethree sets with this problem. |