Dicas Reparação




Modelo - Chassis KV32XBR65


Pesquisa: KV32XBR65 Enviar Dica Resolvida
Resultados 28
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyKV32XBR65
NO PIX OR SOUND, BUT HAS HIGH VOLTAGE, REPLACED D658, R619 Unit had hi-v, but no pix or sound. I turned up the screencontrol and found that vertical deflection was absent, and horizontal wasreduced. Checked vert. output - normal. Found IC301-47 (SCL) and 48 (SDA)lines to have low DC. Q170 base voltage also low.
SonyKV32XBR65
NO PICTURE, NO SOUND, NO HIGH VOLTAGE, REPLACED C672 No pix, no sound, no high voltage. +9 Volt and +5 Voltregulator IC's on main PCB output low. Input, also low. Found +18 VoltSPC to be +7 Volt DC loaded and only +13 Volt DC unloaded, found filtercap C672 open.
SonyKV32XBR65
HOR. OUTPUT FAILURE, SEE SB 161R1 Dead Hor. Output Q-503 failed.
SonyKV32XBR65
LINES IN PICTURE, REPLACED R-527 Lines on picture.
SonyKV32XBR65
BLACK LINES IN PICTURE, REPLACED R1511 ON THE "D" BOARD Unit had black horizontal lines that would start at the top ofpicture. They would go 4-5 inches down. After more warm up black lineswould start at bottom and move up 4-5 inches.
SonyKV32XBR65
NO POWER, REPLACED Q-604 B+ supply only +5Vdc on B+ line. Ran F bd. separatelyw/lightbulb load on plug F-61 at pins 1 & 4. Pins 8 & 9 on IC-651 had-.2Vdc on them. Found Q-604 shorted emitter to collector & R-610 open.These don't exist on schematic. Please correct manuals wit
SonyKV32XBR65
INT. PIC SHRINKING/TROUBLE SHOOTING TIP FOR POWER SUPPLY I have had several XBR sets with complaints of intermittentpicture shrinking. The solution was no regualtion of the B+ which waslowering under load. Here is a simple procedure that can be used whentrouble shooting this type of failure: Operate the set wi
SonyKV32XBR65
HORIZONTAL CENTERING PROCEDURE MISSING FROM SM, SEE SB 102 The horizontal centering adjustmnet on page 30 of the servicemanual omits the fact that a horizontal centering tap exists as shown onpage 36, the F board. If the remote commander adjustment is made withthe tap in the wrong place, some sets will exhibit
SonyKV32XBR65
P/N FOR ANODE CONNECTOR MISSING, 1-540-006-32 When replacing the A Board, the wire from the flyback ismissing. Is there a part number for it? -HQ COMMENTS: Please order Part Number 1-540-006-32, which isthe Anode Cable. Future boards will come with this Board.
SonyKV32XBR65
TUNER DRIFTS ON LOW BAND, REPLACED TUNER Channels 2-6 would drift.
SonyKV32XBR65
PICTURE FADES OUT AFTER 10-15 MINUTES, NO HEATER VOLTAGE Unit would power up normally but after 10-15 minutes the pic-ture would fade out. Sound was normal. After picture was lost, scopingthe heater terminals on the C PCB showed no filament voltage to the CRT.
SonyKV32XBR65
SET GOES INTO OVP INTERMITTENTLY ON TURN ON, REPLACE Q-651 Set goes into OVP intermittently on turn on (every 4 or 5times). When unit works, all voltages are correct.
SonyKV32XBR65
IC-101 DOES NOT MATCH PART NUMBER IN MANUAL, SEE SB 92 Above part number does not match with the part called for inthe Service Manual. -HQ COMMENTS: During production, the microprocessor was changed.These two IC are not interchangable. Please check to see what micro isbeing used before ordering from KCP.
SonyKV32XBR65
SRS DISTORTION, SEE SB 45R1 SRS distortion.Solution: Replaced SRS Moduel -HQ COMMENTS: Please replace the moduel with the new one as perservice Bulletin 045.SRS Moduel 8-741-592-02Moduel Bracket 4-393-435-05
SonyKV32XBR65
LOUD HIGH PITCHED NOISE FROM SET, T602 Loud, high pitched noise from set and is not in audio circuit.Sounds similar to yoke with singing problem. Before replacing yoke pleaseread.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.