SintomaCausaSoluçãoPor:
SonyKV32XBR37
AA-1
NO RASTER KV32XBR37 serial 80139945. Unit has no raster. Has sound, CRT filaments, and high voltage. Led in front is flashing Tech may have a IK failure. When bringing up the G2 the raster will appear with full vertical sweep and a purple screen. Not much green. Tech needs to look at the IK buffer collectors on Q771, Q772, & Q773. Normally with beam current there shall be about 1 volt on each collector. With the CRT Socket removed all collectors must drop to ""0"" volts. Q771 did not. It was 1.2 volts regardless if the tube was connected or not. Tech needs to short Q771(E&B) and see if the collector will drop. It did not. TV will need a replacement Q771. Replacement cured the symptom. ""Muller
SonyKV32XBR37
INTERFERENCE ON CHANNEL 55, REPLACED TUNER Customer complained of interference, beat patters, onchannel 55 cable. Not visible in PIP picture/tuner.
SonyKV32XBR37
INTERMITTENT ON/OFF WITH VERTICAL LINEARITY DISTORION Unit intermittly did not come on. When it did itdisplayed poor vertical linearity.
SonyKV32XBR37
NO PICTURE, R701 Customer complain of no picture, dark screen. Voltage checkon C board showed low G2 voltage on pin 5 of CRt socket. CN702 pin 1measured 1000v, resistance test of R701 showed open resistor.
SonyKV32XBR37
NO POWER BUT RELAY CLICKS, REPLACED C684 ON D BOARD The unit has no power but relay clicks and has sound.
SonyKV32XBR37
NO POWER, REPLACED T502 Unit has no power. Found collector voltage of Q502 low and R517/518 gets hot. T502 cause of problem.
SonyKV32XBR37
INTERMITTENT DATA/REPLACE IC102 M BD/WRONG PART LISTED Page 92 of S/M has IC 102 listed incorrectly. The actual part is a ST24C02CB1 and should be listed as 875928074. - HQ COMMENTS: We will check into this and issue a Service Bulletin.
SonyKV32XBR37
NO MAIN PIX, REPLACED COMB FILTER Had child pix but no main pix. Traced video to CN157/pin 8(Video in) on the UA Board. Video input to comb filter Module CN1201was OK. Had no C or Y output from filter CN157/pins 2 & 4. Jumpered V into Y and C out and got main picture back.
SonyKV32XBR37
PIX VERY DARK, REPLACED IC301 ON "M" BOARD Unit had a very dark picture.
SonyKV32XBR37
CANNOT OPERATE PANASONIC VCR WITH TV REMOTE, RMY122 The RMY122 remote that comes with the set can not operate94 model Panasonic VCR's. HQ COMMENTS: The Tech. Dept. has a limited amount of upgraded RMY122remotes that contain the 94 VCR Panasonic codes.
SonyKV32XBR37
FLYBACK PART NUMBER INCORRECT, CORRECT P/N 1-453-146-11 The part number for the Flyback on page 87 of the S/M is incorrect. -HQ COMMENTS: Please refer to Service Manual correction -1. Incorrect Correct 1-453-416-11 1-453-146-11
SonyKV32XBR37
DEAD, VERT SHRUNK FROM BOTTOM AND HOR LINES, REPAIRED FOIL First, hor circuit wouldn't start and temporary jumper wasinstalled to complete open grounds. Then vert deflection was aobut 2short at bottom and fine black hor lines spaced about 1/2' covered raster.Found open foil on board at CN116 pin 11, this pin ca
SonyKV32XBR37
NO PICTURE, RESOLDERED R458 ON UA BOARD Display was present but picture was missing. Serial data wasabsent from IC402/Pin 20, on the UA board. The DC voltage therewas only 2V instead of the expected 5V.
SonyKV32XBR37
CHANNEL POP IN HEADPHONES, REMOVE R193 FROM "A" BOARD When changing main channel, audio pop noise is heard inthe headphone only, other audio outputs are OK. -HQ COMMENTS: Please remove from the A Board R193. This resistor islocated between the tuner mute pin and ground. Please use a low heatsoldering ir


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.