Modelo - Chassis KV32XBR15


Pesquisa: KV32XBR15 Enviar Dica Resolvida
Resultados 38
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyKV32XBR15
PIX SHRINKS AND GOES OFF AFTER A FEW MINUTES, REPLACED C665 This is the third set I have had with this problem. Thinkpoor solder connection on cap caused cap to vent.
SonyKV32XBR15
HOR. OUTPUT FAILURE, SEE SB 161R1 Dead Hor. Output Q-503 failed.
SonyKV32XBR15
BRIGHT SCREEN WITH RETRACE LINES, REPLACED L701 Bright screen with retrace lines. Missing 200v to the RGBoutputs. -SOLUTION found L701 open.
SonyKV32XBR15
NEW MCB, V PRODUCED WHITE CHILD PICTURE., JUMPER R1139 MISS Original problem was many white speckles on otherwisenormal child picture. MCB, V was substituted from a working set and theproblem eliminated. New replacement MCB, V produced a white child pix,washed-out child video with no detail. A second replaceme
SonyKV32XBR15
NO OPERATION / REPLACE IC-101 (MICRO)
SonyKV32XBR15
RED BLOOMING, CONSTANTLY CHANGING WHILE WATCHING PIX, C311 While watching any source, the intensity of red would increaseand decrease slowly (5-10 seconds to fade up and then back down).
SonyKV32XBR15
POWER STAYS ON WITH THE TV TURNED OFF, REPLACED RY101 When the customer turns the power off, the TV remains on.
SonyKV32XBR15
BAD PINCUSHION, Q-505 GETS HOT, REPLACED L501 Servicer had problem with pincushion. Replaced R-571, Q-505and D-512. checked L-501 and thought it was ok. It read about 2 Ohms andit should be approximately 4.5 Ohms. I suggest a service bulletin beissued concerning the above. -HQ COMMENTS: Please
SonyKV32XBR15
CHANNEL CHANGES BY ITSELF, REPLACED IC-1701 Channels keep changing by themselves.
SonyKV32XBR15
NO PICTURE OR SOUND, REPLACED IC-442, AND IC-443 Change IC-442 and IC-443. Data line was grounded. Disconnec-ted pin No. 10 (SDT) on both ICs. Set will operate. -HQ COMMENTS: Thank you for your report. Please check the cause of theshort circuit next time and report to us.
SonyKV32XBR15
BUZZING ON CHANNEL 11, ADD ATTENUATION Buzzing noise on channel 11 (Sunshine Cable) which gets worsewhen SRS system is ON. Tried a working KV27XBR in customer's home and italso does the same thing. Customer had another brand name set which Ihooked up to the same cable outlet and had no prob
SonyKV32XBR15
HORIZONTAL CENTERING: SERVICE MANUAL PROCEDURE, SEE SB # 102 The horizontal centering adjustment on page 30 of the servicemanual omits the fact that a horizontal centering tap exists as shown onpage 36, the F board. If the remote commander adjustment is made withthe tap in the wrong place, some sets will exhibit
SonyKV32XBR15
INTERMITTENT BLACK BAR IN PICTURE, REPLACED THE CRT Had a 3-4 inch black band at the top of the CRT. G-1and G-2 measured 86V. Tapping on the neck of the CRT, unit flashed andthen had a black band at the top of CRT and the bottom was all red.Measured G-2 was about 150V. At times G-2 would jump to about
SonyKV32XBR15
ANODE CONNECTOR MISSING, 1-540-006-32 When replacing the A Board, the Anode wire from the flybackis missing. Is there a part number for it? -HQ COMMENTS: Please order part number 1-540-006-32 which isthe Anode Cable. Future boards will have the cable with the board.
SonyKV32XBR15
SET IN-OPERATIVE, REPLACED IC-651, AND Q604 Unit is inoperative. IC-651 was found defective.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.