SintomaCausaSoluçãoPor:
SonyKV32HSR10
H OUTPUT TRANSISTOR FAIL, REPLACE T501 H output transistor was running hot. Checked waveform at H output transistor and found ringing in it.
SonyKV32HSR10
NO PIN CUSHION CORRECTION AND R518 IS OPEN, L507,R518 Unit came in with a severe pincushion problem, R518 foundopen, the new replacement resistor burned immediately. Found the value ofL507 had changed. Appears excessive AC current passing thru the resistordue to the change of impedance of L507.
SonyKV32HSR10
NO PINCUSHION--CHECK Q505 SILKSCREEN IS WRONG Complaint was distorted pix, found no pin correction.Servicer replaced shorted Q505, as well as L501, R571, and R518. Still hadno pin correction. While examining Q505 again, noticed that the boardsilkscreen is wrong, it shows L503 on base and D508 cathod
SonyKV32HSR10
"X" BOARD PART NUMBER, 8-752-035-54 People order part number 1-629-624-11 ( X board) when theyreally need part number 8-752-035-54 (IC-251). This generates customercomplaints because 1-629-624-11 is a blank board. since this is not wantthe servicer needs the servicer has to reorder the c
SonyKV32HSR10
NO POWER, R660 OPEN Unit would not power up, 135 woult not come up even withF-61 lifted.-SOLUTION :Found R660 open.
SonyKV32HSR10
LOW BRIGHTNESS, RE-SOLDERED T-500/PINS 4 AND 5 Very low brightness for the first five to ten minutes afterturn on P P voltage at H1 and H2 50% off, increases to normal within 10minutes.
SonyKV32HSR10
HOR. OUTPUT FAILURE, SEE SB 161R1 Dead Hor. Output Q-503 failed.
SonyKV32HSR10
EXCESSIVE WIDTH, REPLACE L501 The unit had excessive width. The pin output/Q505 and pindriver/Q504 were initially replaced with no improvement. L501 had beenoverheated and developed shorted turns.
SonyKV32HSR10
PICTURE INTERFERENCE, REPLACED CM-1301 (COMB FILTER) Strange looking black, very small, squiggly lines rainingthroughout the picture background from top to bottom.
SonyKV32HSR10
PENCIL-THIN LINES OF INTERFERENCE IN PIX, D-1514 AND R-527 Screen displayed pencil-thin lines of interference, poor in-terference and set had a high pitched oscillation. I had seen this symp-tom before which was caused by an open R-527. R-527 was also open on theA board. In searching for the cause static resi
SonyKV32HSR10
REMOTE INOPERATIVE, REPLACED C-1701 AND C-1702 OF "A" BOARD Remote inoperative on all functions. Scope showed remote sig-nal going into IC-1701 but no output. All voltages were present or veryclose.
SonyKV32HSR10
INT. PIC SHRINKING/TROUBLE SHOOTING TIP FOR POWER SUPPLY I have had several XBR sets with complaints of intermittentpicture shrinking. The solution was no regualtion of the B+ which waslowering under load. Here is a simple procedure that can be used whentrouble shooting this type of failure: Operate the set wi
SonyKV32HSR10
SHUTS DOWN, "F" BOARD Q-651 E-B OPEN Shut down. Found B+ 135V running between 136 and 142vdc. Iknew either the load was open or our B+ was not regulating. Removed the Fboard from the TV and jumped RY-601. I used a 60 watt lightbulb as my loadon the +135 volt line. Using the variac while mo
SonyKV32HSR10
HORIZONTAL CENTERING: SERVICE MANUAL PROCEDURE, SEE TVP0102 The horizontal centering adjustment on page 30 of the servicemanual omits the fact that a horizontal centering tap exists as shown onpage 36, the F board. If the remote commander adjustment is made withthe tap in the wrong place, some sets will exhibit
SonyKV32HSR10
ANODE CONNECTOR MISSING FROM "A" BOARD, 1-540-006-32 When replacing the A board, the anode wire from the flybackis missing. Is there a part number for it? -HQ COMMENTS: Please order part number 1-540-006-32 which is the AnodeCable. Future Boards will come with this Cable.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.