SintomaCausaSoluçãoPor:
SonyKV2093R
INTERMITTENT SHUTDOWN, RESOLDERED R544 The unit would shut dhown at random. Loss of supply voltageto IC301 would follow.
SonyKV2093R
DARK PICTURE, REPLACED IC651 Dark picture.
SonyKV2093R
BLANKING PROBLEM (UNUSUAL), REPLACED C-1504 Unit had unusual blanking problem. Top half of screen blankedbottom half looked like out of horizontal SYNC. Also, no up and downcontrol with volume and channel functions.
SonyKV2093R
ON-SCREEN DISPLAY MADE PICTURE DIM, IC-104 Anytime set displayed on-screen display the brightness levelof the picture would go very dark. As soon as on-screen display dis-appeared, picture brightness was normal.
SonyKV2093R
INTERMITTENT BRIGHTNESS SHIFT, REPLACE RV-707 SUB BRT Complaint was intermittent shift 17 brightness level. Al-though the sub-brightness control checked ok, replacement eliminated thecomplaint. This the third set of this type that I have had this problemwith this control. Sometimes spraying coolant on th
SonyKV2093R
LOOSES MEMORY, REPLACE MEMORY IC102 Looses memory after a period of time.
SonyKV2093R
PICTURE BOUNCE, REPLACE IF BLOCK After about 15 min. picture would bounce and with the audioreceiving both SAP and MAIN there was a pop in the right channel. Videoin was good. Found this to be heat related as cooling if block unit wouldgo back to normal.
SonyKV2093R
NO FUNCTIONS, A-12 CONNECTOR NOT IN Plugging in unit, unit would come on with hi-voltage, nosound, no raster. Sleep light would come on. Found no VP signal onPin 9 of IC101.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.