SonyKV1952RX
NO AUDIO, REPLACED IC601, STK563F 8-749-956-30 ON A BOARD Found IC 601 bad.
SonyKV1952RX
P/N NOT IN S/M, M BLOCK HOLDER, P/N 4-359-114-01 Part not listed. -HQ COMMENTS: The part # for the M block holder is 4-359-114-01, butit is not stocked in KC. It can be had on special order from Japan.
SonyKV1952RX
RETRACE LINES AND SLIGHT FOLD-OVER AT TOP OF RASTER Retrace lines and slight fold-over at the top of the raster.Dealer called me regarding this problem, also intermittent.
SonyKV1952RX
NO PART NUMBER FOR CP003, 1-417-087-00 No part number in the service manual for CP003 located onthe MU board.
SonyKV1952RX
NO RASTER, NO VOLUME, NO CHANNEL DISPLAY, REPLACE Q2002 No raster at turn on. Raster may be seen for 1/2 second. Novolume, no channel display, B+ present, high voltage present.
SonyKV1952RX
SNOWY PICTURE, REPLACE VHF TUNER This unit produced a snowy picture, the problem being causedby a defective tuner block. We have had reports of a few of these tunersfailing after only a couple of months usage.
SonyKV1952RX
DEAD, REPLACE HDT T501 Unit came in dead, found horizontal output (2SD1938) shortedand fuse open. After replacing output transistor and fuse, foundincorrect waveform on horizontal drive transistor. Found HDT (T501) tobe defective.
SonyKV1952RX
NO FUNCTIONS, REPLACE X2001 No remote or manual functions. Channel indicator lamps didnot come on. This is the 2nd one I have found. I have also had 3servicers that have had the same problem.
SonyKV1952RX
DARK PICTURE, REPLACE C530 AND R538 Dark picture gave impression of insufficient high voltage.In addition the red convergence was off slightly (like H. stat controlslightly misadjusted).


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.