SonyKV1926R
RADIO INTERFERENCE, SEE SB CTV0288RThe picture remains free of interference, but the sound ispicking up the transmission. Even with the unit turned off, the sound isstill there. The customer has an amateur radio station.
SonyKV1926R
CB INTERFERENCE, SEE SB CTV288R CB interference heard from the speaker, even when the set isoff. -HQ COMMENTS: Please refer to service bulletin No. CTV288R.
SonyKV1926R
WEAK AFT LOCK, REPLACED PRESCALER Weak AFT lock when changing channels. Intermittent and notaffected by heat, cold or vibration. Unit would also detune after playingfor sometime. Data signal at prescaler would change with drift.
SonyKV1926R
PICTURE SHIFTED INTERMITTENTLY, REPLACED FREQ. SYNTHESIZER When this unit first turned on, picture was fine. Sometimean hour later, sometime a half day later picture was shifted.
SonyKV1926R
INTERMITTENT CONVERGENCE, CRT This unit has intermittent convergence caused by the tube.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.