Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | KV1554R | THIRD CHANNEL POSITION STUCK IN HIGH BAND | The third channel position (normally channel 4) was stuck inthe HIGH band. All other channel positions worked properly. The problemwas caused by D-005 on the M-1 board. The diode checked good with a DVMin the diode test position. A common failure wit | ||
Sony | KV1554R | SMOKING R613 | As soon as master power switch S901 was turned on, R613 wouldsmoke. TV also would not start up when power switch S001 was pushed.Bridging RY601 contacts stopped resistor from smoking, and set appearedto work normally. | ||
Sony | KV1554RWP | INTERMITTENT ON/OFF | Will come on intermittently. |