SonyKPR46EX20
INTERMITTENT SHUT DOWN, REPLACED OVP TRANSISTOR Q621 Set shuts off intermittently.
SonyKPR46EX20
POWER SWITCH DOES NOT SPRING BACK WHEN PUSHED, 4-393-780-01 The power switch does not spring back when pushed. There is aplastic part missing from the unit - a white piece approximately two inchsquare that is screwed to the front bezel and couples the button to theswitch. The plastic piece and screws are missin
SonyKPR46EX20
BURN SPOTS ON ALL CRTS, REPLACED OPEN R-519 Servicer reported three damaged CRTs in customer set.Troubleshooting of set revealed that R-519 was open.
SonyKPR46EX20
INTERMITTENT SHUT DOWN, REPLACED Q-617 The unit would very intermittently shut off. The initial pro-blem appeared to be a typical high voltage shut down. Closer examinationshowed that it was caused by activation of the OVP line from the switchingpower supply G board. This was caused by a t
SonyKPR46EX20
VERTICAL FOLD OVER, REPLACED C-5003 Vertical stretched and fold over.
SonyKPR46EX20
SCREEN BRIGHTNESS, NORMAL Top and bottom 1/2 of picture is brighter than center.Brightness coming from green tube as it is visible and more pronouncedlooking through lens. Servicer checked four other units at dealer. Allunits display this symptom (PT boards were switched with b
SonyKPR46EX20
DEAD, SEE SERVICE BULLETIN 95R1 When Q-601 and/or Q-602 is replaced, the replacement numberthat is most commonly used is 8-729-926-03. Thus, a backorder for thispart is created. -HQ COMMENTS: Please note that there are 2 part numbers availableas replacement: 8-729-926-03 (2SC4581 N-T


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.