Dicas Reparação




Modelo - Chassis KP53S15


Pesquisa: KP53S15 Enviar Dica Resolvida
Resultados 6
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyKP53S15
RA1
smear KP53S15 Unit has a green smear When tapping on green CRT the picture the picture will smear. Tapping Muller
SonyKP53S15
CUSTOMER CONVERGENCE IS NOT RETAINED. IC003 Customer would adj his convergence and picture settings andthe next time they turned the set on the adjustments were lost. SOLUTION: The memory IC for the customer controls is IC003. The memory IC for Dynamic Convergence is IC005.Note:
SonyKP53S15
RUBBER CAP AS PER I/M PART NUMBER4-050-330-01 Instruction Manual shows rubber caps as a accessorie, butdoes not give a part number. Nor, does this part appear in the ServiceManual. -HQ COMMENTS: The part number for these caps are 4-050-330-02.
SonyKP53S15
FM RADIO RECEPTION THROUGH TV SPEAKERS, SEE MOD BELOW Customer reported FM radio signal when volume was turned allthe way down or if mute was used. This happened in any mode , tuner,video etc. whether or not cables or antenna were connected. Customerlives 1-2 miles from tranmission tower.
SonyKP53S15
UNIT SHUTS DOWN IN VIDEO MODE/ ADJ G2 Unit had no picture intermittently in Video 1 mode. Unit had no problem while in TV mode but when switch to video 1 it wouldblank out.
SonyKP53S15
SHUT DOWN,REPLACED IC-761 Unit going into shut down, traced problem using trainingmanual IC761 shorted.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads