Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | KP53S15 RA1 | smear | KP53S15 Unit has a green smear | When tapping on green CRT the picture the picture will smear. Tapping | Muller |
Sony | KP53S15 | CUSTOMER CONVERGENCE IS NOT RETAINED. IC003 | Customer would adj his convergence and picture settings andthe next time they turned the set on the adjustments were lost. SOLUTION: The memory IC for the customer controls is IC003. The memory IC for Dynamic Convergence is IC005.Note: | ||
Sony | KP53S15 | RUBBER CAP AS PER I/M PART NUMBER4-050-330-01 | Instruction Manual shows rubber caps as a accessorie, butdoes not give a part number. Nor, does this part appear in the ServiceManual. -HQ COMMENTS: The part number for these caps are 4-050-330-02. | ||
Sony | KP53S15 | FM RADIO RECEPTION THROUGH TV SPEAKERS, SEE MOD BELOW | Customer reported FM radio signal when volume was turned allthe way down or if mute was used. This happened in any mode , tuner,video etc. whether or not cables or antenna were connected. Customerlives 1-2 miles from tranmission tower. | ||
Sony | KP53S15 | UNIT SHUTS DOWN IN VIDEO MODE/ ADJ G2 | Unit had no picture intermittently in Video 1 mode. Unit had no problem while in TV mode but when switch to video 1 it wouldblank out. | ||
Sony | KP53S15 | SHUT DOWN,REPLACED IC-761 | Unit going into shut down, traced problem using trainingmanual IC761 shorted. |