Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | KP46S15 RA1 | no turn on | KP46S15 Unit will not turn on. At no time can a ""Click"" be heard from the ""G"" board when the power is applied or when the power is turned on. "" | I had the tech measure the Standby B+ at the input of IC652(1) The voltage should be 24 vdc. We only had 9 volts. Checking with an oscilloscope we found 22 volts peak to peak on the input of the regulator. Unit had defective C667 a 470mfd@ 35 vdc. Replacing the capacitor corrected the | Muller |
Sony | KP46S15 RA1 | Dead | Unit will not turn on. At no time can a ""Click"" be heard from the ""G"" board when the power is applied or when the power is turned on. "" | I had the tech measure the Standby B+ at the input of IC652(1) The voltage should be 24 vdc. We only had 9 volts. Checking with an oscilloscope we found 22 volts peak to peak on the input of the regulator. Unit had defective C667 a 470mfd@ 35 vdc. Replacing the capacitor corrected the | Muller |
Sony | KP46S15 RA1 | Dead | Unit has an overheated standby transformer. The 20 volt source is running at 3 volts. | I had tech disconnect the connectors to the ""M"" board M CN653 on the ""G"" board. This removed the load on the 20 volt stand by and let the 12 volt stand by to rise to near 20 volts too. It is possible we have two regulators bad IC652 and IC001. IC001 may have been damaged by too much voltage on its input because of a defective IC652. OR there is a severe load on the output of IC001 the 5 volt standby on the ""M"" board where the 12 volt stand by enters on connector CN053 Pin 1 then to the IC001 a post 5 volt regulator. There is also a 1000 mfd @ 6.3 vdc on the output of the 5 volt post reg. Suggest the tech bring out both regulators and the capacitor C002 as a precaution. "" | Muller |
Sony | KP46S15 RA1 | Dead | DEAD. Unit has leaking CRT's. Both red and blue CRT's are noticeably leaking with the green showing signs of moisture around the expansion chamber. | Unit will need replacement CRT and the convergence output IC's. | Muller |
Sony | KP46S15 RA1 | dead | KP46S15. Unit has an over heated stand by transformer. The 20 volt source is running at 3 volts. | I had tech disconnect the connectors to the ""M"" board M CN653 on the ""G"" board. This removed the load on the 20 volt stand by and let the 12 volt stand by to rise to near 20 volts too. It is possible we have two regulators bad IC652 and IC001. IC001 may have been damaged by too much voltage on its input because of a defective IC652. OR there is a sever load on the output of IC001 the 5 volt standby on the ""M"" board where the 12 volt stand by enters on connector CN053 Pin 1 then to the IC001 a post 5 volt regulator. There is also a 1000 mfd @ 6.3 vdc on the output of the 5 volt post reg. Suggest the tech bring out both regulators and the capacitor C002 as a precaution. As a idea this board can be worked on outside of the "" | Muller |
Sony | KP46S15 RA1 | Dead | KP46S15 serial 9013723 DEAD. Unit has leaking CRT's. Both red and blue CRT's are noticeably leaking with the green showing signs of moisture around the expansion chamber | Unit will need replacement CRT and the convergence output IC's. | Muller |
Sony | KP46S15 RA1 | CRT | Unit has leaking CRT. Unit has convergence. Both red and green CRT are leaking coolant. Damage is localized to just the CRT's. | Unit will need replacement red and green CRT's. | Muller |
Sony | KP46S15 RA1 | CRT | KP46S15 serial 9013364 Unit has leaking CRT Unit has convergence. Both red and green CRT are leaking coolant leak. Damage is localized to just the CRT's. | Unit will need replacement Red and green CRT's | Muller |
Sony | KP46S15 | CUSTOMER CONVERGENCE IS NOT RETAINED. IC003 | Customer would adj his convergence and picture settings andthe next time they turned the set on the adjustments were lost. SOLUTION: The memory IC for the customer controls is IC003. The memory IC for Dynamic Convergence is IC005.Note: | ||
Sony | KP46S15 | SPOTS ON SCREEN, REPLACED SCREENS | Have seen two units so far with spots in between diffusionscreens. | ||
Sony | KP46S15 | RUBBER CAP AS PER I/M PART NUMBER4-050-330-01 | Instruction Manual shows rubber caps as a accessorie, butdoes not give a part number. Nor, does this part appear in the ServiceManual. -HQ COMMENTS: The part number for these caps are 4-050-330-02. | ||
Sony | KP46S15 | NO POWER, REPLACED F1601 (FUSE 15V) DUE TO D673 OPEN | Unit has no power, found F1601 on D board is open. | ||
Sony | KP46S15 | POOR FOCUS AND CONVERGENCE,ADJ FOCUS & CONVERGENCE | Customer reported ghosts in picture analysis showed porconvergence and edge focus. | ||
Sony | KP46S15 | UNIT DEAD, Q601, 602, R606, AND IC701 | Dead. |