SonyKP46S15
RA1
no turn on KP46S15 Unit will not turn on. At no time can a ""Click"" be heard from the ""G"" board when the power is applied or when the power is turned on. ""I had the tech measure the Standby B+ at the input of IC652(1) The voltage should be 24 vdc. We only had 9 volts. Checking with an oscilloscope we found 22 volts peak to peak on the input of the regulator. Unit had defective C667 a 470mfd@ 35 vdc. Replacing the capacitor corrected the Muller
SonyKP46S15
RA1
Dead Unit will not turn on. At no time can a ""Click"" be heard from the ""G"" board when the power is applied or when the power is turned on. ""I had the tech measure the Standby B+ at the input of IC652(1) The voltage should be 24 vdc. We only had 9 volts. Checking with an oscilloscope we found 22 volts peak to peak on the input of the regulator. Unit had defective C667 a 470mfd@ 35 vdc. Replacing the capacitor corrected the Muller
SonyKP46S15
RA1
Dead Unit has an overheated standby transformer. The 20 volt source is running at 3 volts. I had tech disconnect the connectors to the ""M"" board M CN653 on the ""G"" board. This removed the load on the 20 volt stand by and let the 12 volt stand by to rise to near 20 volts too. It is possible we have two regulators bad IC652 and IC001. IC001 may have been damaged by too much voltage on its input because of a defective IC652. OR there is a severe load on the output of IC001 the 5 volt standby on the ""M"" board where the 12 volt stand by enters on connector CN053 Pin 1 then to the IC001 a post 5 volt regulator. There is also a 1000 mfd @ 6.3 vdc on the output of the 5 volt post reg. Suggest the tech bring out both regulators and the capacitor C002 as a precaution. ""Muller
SonyKP46S15
RA1
Dead DEAD. Unit has leaking CRT's. Both red and blue CRT's are noticeably leaking with the green showing signs of moisture around the expansion chamber. Unit will need replacement CRT and the convergence output IC's. Muller
SonyKP46S15
RA1
dead KP46S15. Unit has an over heated stand by transformer. The 20 volt source is running at 3 volts. I had tech disconnect the connectors to the ""M"" board M CN653 on the ""G"" board. This removed the load on the 20 volt stand by and let the 12 volt stand by to rise to near 20 volts too. It is possible we have two regulators bad IC652 and IC001. IC001 may have been damaged by too much voltage on its input because of a defective IC652. OR there is a sever load on the output of IC001 the 5 volt standby on the ""M"" board where the 12 volt stand by enters on connector CN053 Pin 1 then to the IC001 a post 5 volt regulator. There is also a 1000 mfd @ 6.3 vdc on the output of the 5 volt post reg. Suggest the tech bring out both regulators and the capacitor C002 as a precaution. As a idea this board can be worked on outside of the ""Muller
SonyKP46S15
RA1
Dead KP46S15 serial 9013723 DEAD. Unit has leaking CRT's. Both red and blue CRT's are noticeably leaking with the green showing signs of moisture around the expansion chamber Unit will need replacement CRT and the convergence output IC's. Muller
SonyKP46S15
RA1
CRT Unit has leaking CRT. Unit has convergence. Both red and green CRT are leaking coolant. Damage is localized to just the CRT's. Unit will need replacement red and green CRT's. Muller
SonyKP46S15
RA1
CRT KP46S15 serial 9013364 Unit has leaking CRT Unit has convergence. Both red and green CRT are leaking coolant leak. Damage is localized to just the CRT's. Unit will need replacement Red and green CRT's Muller
SonyKP46S15
CUSTOMER CONVERGENCE IS NOT RETAINED. IC003 Customer would adj his convergence and picture settings andthe next time they turned the set on the adjustments were lost. SOLUTION: The memory IC for the customer controls is IC003. The memory IC for Dynamic Convergence is IC005.Note:
SonyKP46S15
SPOTS ON SCREEN, REPLACED SCREENS Have seen two units so far with spots in between diffusionscreens.
SonyKP46S15
RUBBER CAP AS PER I/M PART NUMBER4-050-330-01 Instruction Manual shows rubber caps as a accessorie, butdoes not give a part number. Nor, does this part appear in the ServiceManual. -HQ COMMENTS: The part number for these caps are 4-050-330-02.
SonyKP46S15
NO POWER, REPLACED F1601 (FUSE 15V) DUE TO D673 OPEN Unit has no power, found F1601 on D board is open.
SonyKP46S15
POOR FOCUS AND CONVERGENCE,ADJ FOCUS & CONVERGENCE Customer reported ghosts in picture analysis showed porconvergence and edge focus.
SonyKP46S15
UNIT DEAD, Q601, 602, R606, AND IC701 Dead.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.