Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | IVOV11 | DEAD UNIT, REPLACED R543 | When power is switched on, green power light is on for 2-3seconds then it goes out and unit is dead. | ||
Sony | IVOV11 | UNIT WILL NOT POWER ON | FPR# P2469 was submitted on another unit with same problem.Found R539 missing from the PU-4 board. Mounting screw of mech. ispressing on PU4 board where R539 is located. This may be caused bytransporting unit. | ||
Sony | IVOV11 | NO POWER ON, IMMEDIATE POWER OFF | Two units had identical problems. When power was turned ON,LED would light then, immediately turn OFF. Problem was apparentlya power detect symptom of low B+. IC408 is used to detect level of B+.Replacement of IC408 did not restore operation. Further t |