SonyITID500
INTERMITTENT DISPLAY OF ID INFO customer complaint of unit dropping or not showing the O inthe ones column of the date. Every 10th, 20th, 30th of the month thedate would read 6/1-/95, 6/2-/95, 6/3-/95. Customer also stated thatsometimes unit would not display ID info at all, though
SonyITID500
PHONE NOT RECOGNIZING NUMBERS Phone will not read out phone numbers on screen since ..itdoes not recognize number on local calls.
SonyITID500
NO OR INTERMITTENT POWER/DISPLAY - RESOLDER DC JACK. No or intermittent power/display. This is due to the DC JackJ101 being either unsoldered or cold soldered.
SonyITID500
MALFUNCTION OF TELEPHONE NUMBER DISPLAY Unit either has a false date in the display, or sometimes itdoes not display the telephone number.
SonyITID500
HANDSET WON'T HANG UP - REPLACE Q301, P/N 8-729-927-34 Handset won't hang up.
SonyITID500
NO DISPLAY NO FUNCTION - REPLACE IC501 Unit had no display no dial tone, no ring and no keyfunctions however, line light would come on when off hook.
SonyITID500
CALLER ID NOT ALWAYS REGISTERING ON PHONE Customer says that about every 3-4 calls will not register onphone. Caller also has a ATT caller Id box on phone line and it registersevery call. Customer has tried several different hookups and locationswith no difference in symptom. Customer has 2 othe
SonyITID500
NO KEYBOARD FUNCTION No keyboard function.
SonyITID500
TOO MUCH SIDETONE IN HANDSET Customer complains of too much sidetone on handset


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.