Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | ITA505 | DISTORTED AUDIO/TAPE - R526 AND R530 WERE WRONG VALUES | After recording Memo, ICM and conv. rec., there was speakerdistortion during playback. I found R526 value at 68.4 (it should be 100),and R530 value at 119k (should be 270k). The low resistance values of R526and R530 made the output of IC503/pin 7 (amplif | ||
Sony | ITA505 | WRONG PART - RV-501 | RV501 should be 6 leads but when ordered under 1-238-818-11(Page 42) getting wrong part there are only 4 leads. This part will notfit into PC board. -HQ COMMENTS: KCPS checked their stock and found that the correct partnumber is 1-223-171-11. | ||
Sony | ITA505 | POOR AUDIO ON ICM PLAY BACK | Complain about playback is very poor or unclear audio. | ||
Sony | ITA505 | PART NUMBERS NOT AVAILABLE FOR CREAM COLORED CABINETS | There are no part numbers for the ITA505Cream. ITA205-305upper and lower cabinet can be used, but the cassette lid would show thewrong model number. What are the part numbers for the cream color cabinetparts? -HQ COMMENTS: KCP just received the IRP lis | ||
Sony | ITA505 | NO SPEAKER PHONE AND NO DIAL OUT. CHANGE Q-401(8-729-920-74) | The unit will not dial out and the speaker phone will notwork. IC401 did not have key scan data on pins 40-44. Crystal wasrunning. Found reset on IC401/pin 29 to be at zero volts. Q401 wasshorted from C to E. | ||
Sony | ITA505 | WEAK AUDIO IN ICM AND OGM THROUGH THE SPEAKERPHONE | The audio out of the speakerphone is weak for ICM and OGM. | ||
Sony | ITA505 | NO DIAL TONE - REPLACE IC-602, P/N 8-759-246-52 | No dial tone on handset when unit is plugged into AC.Speakerphone is ok. | ||
Sony | ITA505 | IC-602 ON BACK ORDER AT KCP, | ASC reported three units with a bad IC-602. Also applies toserial numbers 120679 and 120596. As of today there are 216 on back orderat NPC. -HQ COMMENTS: We checked with KCP. The estimated time of arrival of theparts is April 15, 1993. | ||
Sony | ITA505 | WILL NOT ANSWER INCOMING CALLS | |||
Sony | ITA505 | WILL NOT ANSWER INCOMING CALLS | Customer complains of unit not answering incoming calls. Unitworks fine in shop. Most of these that we have seen are when the customerlives in a smaller community or rural area. These answering machines seemto have a problem detecting the ring on some | ||
Sony | ITA505 | UNIT CUTTING OFF WHEN CUSTOMER PICKS UP OTHER PHONE | Unit cuts off when customer picks up other phone. -HQ COMMENTS: This problem occurs because when an extension phone ispicked up, the tel line voltage drops below 5 volts and the unit cuts off.A tech flash and a service bulletin have been issued to modif |