Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | HCDD560 | CHASSIS AVAILABLE | No part # available for plastic chassis. | ||
Sony | HCDD560 | HIGH TOP LASER CURRENT ON KSS 213 B/1 | Skipping and related cd problems. Observing RF signal and Inoticed distortion on bottom half of wave. Amplitude was almost 2 volts. Turned down laser curreent on optical until it was 1vpp. RF is now very clear and | ||
Sony | HCDD560 | NO POWER | This is another unit that came in with fuse F1903 open. Found oscillation (about 600KHz) on output IC when volume is up full on unused function. -SOULUTION: Wrapped wires 7&8 to a wire cable from Power Amp BD to Main B | ||
Sony | HCDD560 | MAIN FUSE OPENS -REPLACE F1903 WITH 4A,125V | I have reports from one of my dealers that they are seeing these units coming in with main fuse open. Replacement of main fuse restores operation. This is similar to the comments made about the LBTD560 units. | ||
Sony | HCDD560 | DONESN'T READ CD - RESOLDER JW348 | Unit powers up but does not read cd, no focus ok and no laser on. | ||
Sony | HCDD560 | NO CD, REEL MOTOR, OR FOCUS - RESOLDERED X101 | No CD function, no reel motor, sled motor or focus function.Will load CD. | ||
Sony | HCDD560 | DEAD UNIT - REPLACE F1901, IC1351 AND IC1201(POWER AMP) | Unit came in dead main fuse open and regulator IC burned. |