Dicas Reparação




Modelo - Chassis FD42A


Pesquisa: FD42A Enviar Dica Resolvida
Resultados 7
Pedir dica reparação
MarcaModelo
(Chassis)
SintomaCausaSoluçãoPor:
SonyFD42A
DEAD UNIT, REPLACED IC601 AND Q602 The unit came in with an absence of 32V at IC601/pin 13.Replacing IC601 solved the problem but severe keystoning appeared.Replacing Q602 solved the distortion. -SOLUTIOIN: Replaced IC601 875980239 and Q602 872911155. -HQ COMMENTS: 32 volts on IC601
SonyFD42A
EJ BOARD P/N Part number needed for EJ board, blank former type(without resistor). All three service manuals/FD-42A list only one partnumber for EJ board: 1-621-293-11 and this is for New Type board(with place for resistor). There is no listing for former type EJbo
SonyFD42A
NO PIX, REPLACED Q802, D802, IC601 AND Q602 1. No picture. 2. No high voltage. 3. Bad keystone.1. Weak drive signal on Q801 base.2. Open Q802.3. No drive of pin 5 (IC601) open Q602.
SonyFD42A
NO VIDEO, RESOLDERED Q401 Cold solder on collector of Q401.
SonyFD42A
PICTURE DISPLAYED KEYSTONE, Q602 Picture displayed keystone problem, more severe with batteryoperation than with AC adaptor. See picture. Picture severely pulled intoward center at top of raster, from both sides. Waveform at collector ofQ602 was distorted. Resistance between E to B
SonyFD42A
RV851 AND RV502 ARE REVERSED Vertical size adjustment control RV851 and keystone adj.RV502 are reversed. That is, RV851 is the keystone adj. and RV502 is thesize adj. Schematic is correct. -HQ COMMENTS: We will publish a correction on this.
SonyFD42A
KEYSTONE, REPLACED D602 Unit had keystone problem, traced problem to base of regulatorQ602. Had a 5Vpp (mostly negative) waveform, nothing at collector.Found diode D602 open, not clamping negative half of waveform.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.

Não arrisque reparar equipamentos com tensões elevadas se não tiver conhecimentos técnicos para o fazer em segurança.

Verifique se o esquema está disponível na área de downloads