Marca | Modelo (Chassis) | Sintoma | Causa | Solução | Por: |
---|---|---|---|---|---|
Sony | EVA300U | TAPE PATH ADJUSTMENT UNSTABLE | When attempting to make the tape path adjustments, I found Icould not make the waveform square especially toward the entrance portionof the waveform. The picture in the play mode was fine but in pause thetop portion was distorted or torn. | ||
Sony | EVA300U | UNIT ENTERS SHUTDOWN MODE | When play button is pressed, unit enters shutdown mode. Inoticed that the pinch roller was not engaging the capstan shaft. Inspec-tion revealed that the pinch press lever was jammed. | ||
Sony | EVA300U | INTERMITTENT SHUTDOWN | Unit shuts down intermittently. | ||
Sony | EVA300U | INCOMPLETE REPLACEMENT BOARD | After replacing SS-38B Bd., the remote control worked inter-mittently. While in PLAY, if search button was held down the unit wouldgo into scan for about 1/2 sec. This would repeat about every 3 sec. Intracing the remote signal from the Timer board to | ||
Sony | EVA300U | ERRATIC VIDEO | Unit had erratic video. Found problem to be bad heads. | ||
Sony | EVA300U | TAPE TRANSPORT INOPERATIVE | Tape transport functions inoperative. Mode and load controlmotors and switches check good with checker box. Could not get an outputcommand from microprocessor to run these motors even though the inputs toCPU check good. I found that every other functi |