AMVOXAMD908
quando liga na tomada ele abre a bandeija e acende o led mas nao funciona nadaos dois capacitores das fontes de -12 e +12trocar direto sem medirantonio nobrega (PATOS PB)
AMVOXAMD909
depois de alguns minutos ligado fica reiniciandofotoacopladortrocaloantono nobrega patos pb
LG20D90
nao sintoniza ningun canal!!!capacitores con perdida de capacidade no mismo sintonizador!!!. troca tudos por novos. 47uf 16v... 2,2uf 50v...0.47uf 50vbarnes
SonyEXCD90
CD DOES NOT PLAY, DISPLAY READS E-04 The LCD display of the unit reads E-04. This may be caused bythe CD making contact with the chucking arm (ref# 122). This may cause theCD not to spin and eventually displaying an error message.
SonyEXCD90
UNEXPLAINED ERROR CODE IN TEST MODE: "E-A0" An unexplained error code appeared on the display while in thetest mode. The code is E-A0. -HQ COMMENTS: Tokyo told us that program bugs may account forunexplained error codes. In this particular case, the E-A0 appears whenthe unit tried to eject the
SonyEXCD90
ERROR CODE E44 Servicer has unit that customer complained it dropped out oncein awhile. Servicer has not been able to duplice problem. Put unit intest mode. After 6 hours of playing E44 came up on display but unit kepton playing. Noted FPR 03252. Here's another er
SonyEXCD90
NO AUDIO (FOUND AUDIO AMP IC303 DEFECTIVE) No audio. Found audio amp IC303 defective. -HQ COMMENTS: Tokyo has analyzed samples we sent them and havedetermined that the defects are ususally caused by excessive reversevoltage being applied to the IC, probably by the power antenna relayturning off
SonyEXCD90
KEYSWITCHES FAIL The keyswitches fail. It is most often the SELECT key butcould be any key. Sometimes there are more than 1 bad switch on the samefaceplate. -HQ COMMENTS: The QA group in Tokyo has been notified and samples havebeen sent to them. An improved switch ha
SonyCPD9000
RECOMMENDED SCREEN CLEANER
SonyD90
RUNS IN TEST MODE, SHUTS DOWN IN NORMAL OPERATION Unit would achieve focus, sled would move toward center ofdisk and continue reading T.O.C. data then shutdown. Looking at RF testpoint, showed signal typical of T.O.C. area: FOK, Sense, H. in signalsappeared normal.
SonyCPD9000
CURVATURE OF CRT We need the specification on the curvature (Radius) of theCRT used in this model. -HQ COMMENTS: _______ | |Y= 11560mm |_______| X= 2275mm
SonyCPD9000
DEAD UNIT Unit was received in non-operating condition. Furtherinvestigation led to finding a cracked (DA) Board. (DA) board was re-placed with no luck.


Assistência TécnicaAs dicas apresentadas destinam-se a técnicos de eletrónica, a tentativa de reparação ou assistência sem ter conhecimentos de eletricidade e eletrónica, podem provocar danos mais graves aos equipamentos e, devido a tensões muito elevadas em alguns circuitos, graves danos fisicos que podem constituir um risco em determinadas reparações.